The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented in this paper to validate the operation of the different strategies.

The PWM Strategies of Grid-connected Distributed Generation Active NPC Inverters / Ma, L; Kerekes, T; Teodorescu, R; Jin, X; Floricau, D; Liserre, Marco. - (2009), pp. 920-927. (Intervento presentato al convegno 2009 IEEE Energy Conversion Congress and Exposition tenutosi a San Jose, CA, USA nel 20-24 Sept. 2009) [10.1109/ECCE.2009.5316449].

The PWM Strategies of Grid-connected Distributed Generation Active NPC Inverters

LISERRE, Marco
2009-01-01

Abstract

The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented in this paper to validate the operation of the different strategies.
2009
2009 IEEE Energy Conversion Congress and Exposition
978-142442893-9
The PWM Strategies of Grid-connected Distributed Generation Active NPC Inverters / Ma, L; Kerekes, T; Teodorescu, R; Jin, X; Floricau, D; Liserre, Marco. - (2009), pp. 920-927. (Intervento presentato al convegno 2009 IEEE Energy Conversion Congress and Exposition tenutosi a San Jose, CA, USA nel 20-24 Sept. 2009) [10.1109/ECCE.2009.5316449].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/16077
Citazioni
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 1
social impact