The optimum design of tuned liquid column damper (TLCD) is usually performed by minimizing the maximum response of structure subjected to stochastic earthquake load without imposing any restrictions on the possible maximum oscillation of the liquid within the vertical column. However, during strong earthquake motion, the maximum oscillation of vertical column of liquid may be equal to or greater than that of the container pipe. Consequently the physical behavior of the hydraulic system may change largely reducing its efficiency. The present study deals with the optimization of TLCD parameters to minimize the vibration effect of structures addressing the limitation on such excessive liquid displacement. This refers to the design of optimum TLCD system which not only assure maximum possible performance in terms of vibration mitigation, but also simultaneously put due importance to the natural constrained criterion of excessive lowering of liquid in the vertical column of TLCD. The constraint is imposed by limiting the maximum displacement of the liquid to the vertical height of the container. Numerical study is performed to elucidate the effect of constraint condition on the optimum parameters and overall performance of TLCD system of protection.

Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures / Chakraborty, S.; Debbarma, R.; Marano, Giuseppe Carlo. - In: JOURNAL OF SOUND AND VIBRATION. - ISSN 0022-460X. - 331:7(2012), pp. 1519-1531. [10.1016/j.jsv.2011.11.029]

Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures

MARANO, Giuseppe Carlo
2012-01-01

Abstract

The optimum design of tuned liquid column damper (TLCD) is usually performed by minimizing the maximum response of structure subjected to stochastic earthquake load without imposing any restrictions on the possible maximum oscillation of the liquid within the vertical column. However, during strong earthquake motion, the maximum oscillation of vertical column of liquid may be equal to or greater than that of the container pipe. Consequently the physical behavior of the hydraulic system may change largely reducing its efficiency. The present study deals with the optimization of TLCD parameters to minimize the vibration effect of structures addressing the limitation on such excessive liquid displacement. This refers to the design of optimum TLCD system which not only assure maximum possible performance in terms of vibration mitigation, but also simultaneously put due importance to the natural constrained criterion of excessive lowering of liquid in the vertical column of TLCD. The constraint is imposed by limiting the maximum displacement of the liquid to the vertical height of the container. Numerical study is performed to elucidate the effect of constraint condition on the optimum parameters and overall performance of TLCD system of protection.
2012
Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures / Chakraborty, S.; Debbarma, R.; Marano, Giuseppe Carlo. - In: JOURNAL OF SOUND AND VIBRATION. - ISSN 0022-460X. - 331:7(2012), pp. 1519-1531. [10.1016/j.jsv.2011.11.029]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/2967
Citazioni
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 35
social impact