CMS experiment will use resistive plate chambers (RPCs) as dedicated muon trigger detectors. This requires good chamber global and local performance. To verify the chamber performance intensive tests are going on using a telescope installed at Bari Physics Department. The chamber efficiency is obtained by track reconstruction, which offers also the possibility to perform local efficiency studies. A brief description of the test set-up, reconstruction algorithm and test results are presented in this paper.

The cosmics rays quality test procedure for the CMS barrel resistive plate chambers / Abbrescia, M.; Cavallo, E.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Memoli, V.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F.; Trentadue, R.; Cavallo, N.; Comunale, G.; Fabozzi, F.; Paolucci, P.; Piccolo, D.; Sciacca, C.; Belli, G.; De Vecchi, C.; Guida, R.; Ratti, S. P.; Riccardi, G.; Torre, P.; Vitulo, P.; Anguelov, T.; Genchev, V.; Panev, B.; Piperov, S.; Sultanov, G.; Vankov, P.; Dimitrov, A.; Glushkov, I.; Litov, L.; Nasteva, I.; Pavlov, B.; Petkov, P.; Ban, Y.; Liu, H. T.; Qian, S. J.; Ye, Y. L.; Ying, J.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 533:1-2(2004), pp. 208-213. [10.1016/j.nima.2004.07.029]

The cosmics rays quality test procedure for the CMS barrel resistive plate chambers

Iaselli, G.;Pugliese, G.;
2004-01-01

Abstract

CMS experiment will use resistive plate chambers (RPCs) as dedicated muon trigger detectors. This requires good chamber global and local performance. To verify the chamber performance intensive tests are going on using a telescope installed at Bari Physics Department. The chamber efficiency is obtained by track reconstruction, which offers also the possibility to perform local efficiency studies. A brief description of the test set-up, reconstruction algorithm and test results are presented in this paper.
2004
The cosmics rays quality test procedure for the CMS barrel resistive plate chambers / Abbrescia, M.; Cavallo, E.; Colaleo, A.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Memoli, V.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F.; Trentadue, R.; Cavallo, N.; Comunale, G.; Fabozzi, F.; Paolucci, P.; Piccolo, D.; Sciacca, C.; Belli, G.; De Vecchi, C.; Guida, R.; Ratti, S. P.; Riccardi, G.; Torre, P.; Vitulo, P.; Anguelov, T.; Genchev, V.; Panev, B.; Piperov, S.; Sultanov, G.; Vankov, P.; Dimitrov, A.; Glushkov, I.; Litov, L.; Nasteva, I.; Pavlov, B.; Petkov, P.; Ban, Y.; Liu, H. T.; Qian, S. J.; Ye, Y. L.; Ying, J.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 533:1-2(2004), pp. 208-213. [10.1016/j.nima.2004.07.029]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/9393
Citazioni
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact