In this paper, the experimental validation of a time domain reflectometry (TDR)-based method for pinpointing water leaks in underground metal pipes is presented. The method relies on sensing the local change in the dielectric characteristics of the medium surrounding the leak point. The experimental validation of the method was carried out through measurements performed on a pilot plant (experimental case P1) and through on-the-field measurements performed on two 'already-installed pipes', i.e., already operating and connected to the water distribution system (experimental cases P2 and P3). For the pilot plant, different leak conditions were imposed and the corresponding TDR responses were acquired and analyzed. For the on-the-field measurements, TDR measurements were performed on pipes for which a leak-detection crew had preliminarily individuated the possible presence of leaks (through traditional leak-detection methods). Finally, in view of the practical implementation of the proposed TDR-based leak-detection system, a data-processing procedure (which gives an automatic evaluation of the position of the leak) is also presented.

Experimental validation of a TDR-based system for measuring leak distances in buried metal pipes / Cataldo, A.; Cannazza, G.; De Benedetto, E.; Giaquinto, N.. - In: ELECTROMAGNETIC WAVES. - ISSN 1070-4698. - STAMPA. - 132:(2012), pp. 71-90. [10.2528/PIER12081402]

Experimental validation of a TDR-based system for measuring leak distances in buried metal pipes

Giaquinto, N.
2012-01-01

Abstract

In this paper, the experimental validation of a time domain reflectometry (TDR)-based method for pinpointing water leaks in underground metal pipes is presented. The method relies on sensing the local change in the dielectric characteristics of the medium surrounding the leak point. The experimental validation of the method was carried out through measurements performed on a pilot plant (experimental case P1) and through on-the-field measurements performed on two 'already-installed pipes', i.e., already operating and connected to the water distribution system (experimental cases P2 and P3). For the pilot plant, different leak conditions were imposed and the corresponding TDR responses were acquired and analyzed. For the on-the-field measurements, TDR measurements were performed on pipes for which a leak-detection crew had preliminarily individuated the possible presence of leaks (through traditional leak-detection methods). Finally, in view of the practical implementation of the proposed TDR-based leak-detection system, a data-processing procedure (which gives an automatic evaluation of the position of the leak) is also presented.
2012
Experimental validation of a TDR-based system for measuring leak distances in buried metal pipes / Cataldo, A.; Cannazza, G.; De Benedetto, E.; Giaquinto, N.. - In: ELECTROMAGNETIC WAVES. - ISSN 1070-4698. - STAMPA. - 132:(2012), pp. 71-90. [10.2528/PIER12081402]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/7225
Citazioni
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 22
social impact