Hole drilling is the most widespread method for measuring residual stress. It is based on the principle that drilling a hole in the material causes a local stress relaxation; the initial residual stress can be calculated bymeasuring strain in correspondence with each drill depth. Recently optical techniques were introduced to measure strain; in this case, the accuracy of the final results depends, among other factors, on the proper choice of the area of analysis. Deformations are in fact analyzed within an annulus determined by two parameters: the internal and the external radius. In this paper, the influence of the choice of the area of analysis was analysed. A known stress field was introduced on a Ti grade 5 sample and then the stress was measured in correspondence with different values of the internal and the external radius of analysis; results were finally compared with the expected theoretical value.
Remarks on Residual Stress Measurement by Hole-drilling and Electronic Speckle Pattern Interferometry / Barile, Claudia; Casavola, Caterina; Pappalettera, Giovanni; Pappalettere, Carmine. - In: THE SCIENTIFIC WORLD JOURNAL. - ISSN 2356-6140. - 2014:(2014). [10.1155/2014/487149]
Remarks on Residual Stress Measurement by Hole-drilling and Electronic Speckle Pattern Interferometry
BARILE, Claudia;CASAVOLA, Caterina;PAPPALETTERA, Giovanni;PAPPALETTERE, Carmine
2014-01-01
Abstract
Hole drilling is the most widespread method for measuring residual stress. It is based on the principle that drilling a hole in the material causes a local stress relaxation; the initial residual stress can be calculated bymeasuring strain in correspondence with each drill depth. Recently optical techniques were introduced to measure strain; in this case, the accuracy of the final results depends, among other factors, on the proper choice of the area of analysis. Deformations are in fact analyzed within an annulus determined by two parameters: the internal and the external radius. In this paper, the influence of the choice of the area of analysis was analysed. A known stress field was introduced on a Ti grade 5 sample and then the stress was measured in correspondence with different values of the internal and the external radius of analysis; results were finally compared with the expected theoretical value.File | Dimensione | Formato | |
---|---|---|---|
The Scientific World Journal 2014.pdf
accesso aperto
Tipologia:
Versione editoriale
Licenza:
Creative commons
Dimensione
8.53 MB
Formato
Adobe PDF
|
8.53 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.