Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. Preliminary results on sensitivity to gas changes and to environmental variables will be reported on. (C) 2009 Elsevier B.V. All rights reserved.

Operational Experience of the Gas Gain Monitoring system of the CMS RPC muon detectors / Colafranceschi, S.; Benussi, L.; Bianco, S.; Fabbri, L.; Giardoni, M.; Ortenzi, B.; Paolozzi, A.; Passamonti, L.; Piccolo, D.; Pierluigi, D.; Ponzio, B.; Russo, A.; Colaleo, A.; Loddo, F.; Maggi, M.; Ranieri, A.; Abbrescia, M.; Iaselli, G.; Marangeli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Romano, F.; Roselli, G.; Trentadue, R.; Tupputi, S.; Guida, R.; Polese, G.; Sharma, A.; Cimmino, A.; Lomidze, D.; Paolucci, D.; Baesso, P.; Necchi, M.; Pagano, D.; Ratti, S. P.; Vitulo, P.; Viviani, C.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 617:1-3(2010), pp. 146-147. [10.1016/j.nima.2009.06.095]

Operational Experience of the Gas Gain Monitoring system of the CMS RPC muon detectors

Iaselli, G.;Pugliese, G.;
2010-01-01

Abstract

Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. Preliminary results on sensitivity to gas changes and to environmental variables will be reported on. (C) 2009 Elsevier B.V. All rights reserved.
2010
Operational Experience of the Gas Gain Monitoring system of the CMS RPC muon detectors / Colafranceschi, S.; Benussi, L.; Bianco, S.; Fabbri, L.; Giardoni, M.; Ortenzi, B.; Paolozzi, A.; Passamonti, L.; Piccolo, D.; Pierluigi, D.; Ponzio, B.; Russo, A.; Colaleo, A.; Loddo, F.; Maggi, M.; Ranieri, A.; Abbrescia, M.; Iaselli, G.; Marangeli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Romano, F.; Roselli, G.; Trentadue, R.; Tupputi, S.; Guida, R.; Polese, G.; Sharma, A.; Cimmino, A.; Lomidze, D.; Paolucci, D.; Baesso, P.; Necchi, M.; Pagano, D.; Ratti, S. P.; Vitulo, P.; Viviani, C.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 617:1-3(2010), pp. 146-147. [10.1016/j.nima.2009.06.095]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/8778
Citazioni
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 8
social impact