This paper describes a model able to evaluate the effect of masonry panels on reinforced concrete frames subjected to a seismic action. The panel is modelled as an equivalent diagonal element with a bilinear constitutive relation. The efficacy of the model is verified with an hysteretic model which considers some fundamental characteristics of masonry subjected to a seismic action (transitory phase between elastic and elasto-plastic behaviour, stiffness and strength decay, reduction of the hysteresis cycles due to the opening and closing of the cracks). This study shows that the presence of masonry panels causes a different distribution of the seismic action that usually concentrates in the lower floors (with accumulation of the damage in these levels) and the whole structure keeps in the elastic field.

Nel presente lavoro si descrive un modello in grado di valutare l’influenza delle tompagnature murarie sui telai circostanti in c.a. soggetti ad un’azione sismica. Il pannello murario è modellato attraverso un puntone diagonale equivalente di cui si propone un legame costitutivo semplificato (bilineare) la cui validità è testata per mezzo di un modello isteretico capace di considerare alcune fondamentali caratteristiche della tompagnatura soggetta ad un’azione sismica (la fase di transizione tra comportamento elastico e elastoplastico, il decadimento della rigidezza e della resistenza, il contrarsi dei cicli d’isteresi per effetto dell’apertura e della chiusura delle fessure). Lo studio e il successivo esempio evidenziano importanti conseguenze della presenza della tompagnature ed, in primo luogo, una diversa distribuzione dell’azione sismica che tende a concentrarsi negli impalcati inferiori (con relativo accumulo di danno in tali livelli), con il resto della struttura pressoché in campo elastico.

Influenza delle tamponature sulla statica dei telai in c.a. in zona sismica / Foti, Dora; Borgia, M.. - In: INGEGNERIA SISMICA. - ISSN 0393-1420. - 24:1(2007), pp. 5-16.

Influenza delle tamponature sulla statica dei telai in c.a. in zona sismica

FOTI, Dora;
2007-01-01

Abstract

This paper describes a model able to evaluate the effect of masonry panels on reinforced concrete frames subjected to a seismic action. The panel is modelled as an equivalent diagonal element with a bilinear constitutive relation. The efficacy of the model is verified with an hysteretic model which considers some fundamental characteristics of masonry subjected to a seismic action (transitory phase between elastic and elasto-plastic behaviour, stiffness and strength decay, reduction of the hysteresis cycles due to the opening and closing of the cracks). This study shows that the presence of masonry panels causes a different distribution of the seismic action that usually concentrates in the lower floors (with accumulation of the damage in these levels) and the whole structure keeps in the elastic field.
2007
Influenza delle tamponature sulla statica dei telai in c.a. in zona sismica / Foti, Dora; Borgia, M.. - In: INGEGNERIA SISMICA. - ISSN 0393-1420. - 24:1(2007), pp. 5-16.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/11327
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact