In Distributed Power Generation Systems (DPGS), the control system of the converter, interfacing the electrical source with the main grid, is generally based on a dual loop cascade control structure where the internal loop is in charge of the current control while the outer loop controls the voltage at the DC link. The DC voltage can be subjected to transient conditions due to the change of the power produced by the source. If the system experiences high and abrupt variations of the DC voltage, the control system designed starting from a small signal linearized model can fail. In this paper, a Simplified Feedback Linearization (SFL) control is designed for a single-phase grid-connected converter. The system is compared with a classical dual loop control in terms of stability and dynamics performances. Simulation and experimental results confirms the effectiveness of the SFL control also in case of high variations of the DC voltage reference.

Performance comparison of Simplified Feedback Linearization control with classical dual loop control for single-phase grid-connected inverters / Pugliese, Sante; Mastromauro, Rosa Anna; Gervasio, Francesco Antonio; Stasi, Silvio. - (2016), pp. 6621-6626. (Intervento presentato al convegno 42nd Annual Conference of the IEEE-Industrial-Electronics-Society, IECON 2016 tenutosi a Firenze, Italy nel October 24-27, 2016) [10.1109/IECON.2016.7793622].

Performance comparison of Simplified Feedback Linearization control with classical dual loop control for single-phase grid-connected inverters

Pugliese, Sante;Gervasio, Francesco Antonio;Stasi, Silvio
2016-01-01

Abstract

In Distributed Power Generation Systems (DPGS), the control system of the converter, interfacing the electrical source with the main grid, is generally based on a dual loop cascade control structure where the internal loop is in charge of the current control while the outer loop controls the voltage at the DC link. The DC voltage can be subjected to transient conditions due to the change of the power produced by the source. If the system experiences high and abrupt variations of the DC voltage, the control system designed starting from a small signal linearized model can fail. In this paper, a Simplified Feedback Linearization (SFL) control is designed for a single-phase grid-connected converter. The system is compared with a classical dual loop control in terms of stability and dynamics performances. Simulation and experimental results confirms the effectiveness of the SFL control also in case of high variations of the DC voltage reference.
2016
42nd Annual Conference of the IEEE-Industrial-Electronics-Society, IECON 2016
978-1-5090-3474-1
Performance comparison of Simplified Feedback Linearization control with classical dual loop control for single-phase grid-connected inverters / Pugliese, Sante; Mastromauro, Rosa Anna; Gervasio, Francesco Antonio; Stasi, Silvio. - (2016), pp. 6621-6626. (Intervento presentato al convegno 42nd Annual Conference of the IEEE-Industrial-Electronics-Society, IECON 2016 tenutosi a Firenze, Italy nel October 24-27, 2016) [10.1109/IECON.2016.7793622].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/114175
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact