This document analyses the resistant behaviour to diagonal compression and direct compression of brick masonry specimens, reinforced with textile reinforced mortars (TRM) and without them. The numerical models have been calibrated with experimental results in order to have a suitable technique to reinforce masonry historic constructions where extraordinary tension stresses could occur in seismic situations. For the numerical modelling, FEM models have been developed using non-linear layered bi-dimensional shell elements. Moreover, a comparative analysis has been developed between the numerical models and the experimental ones. There are two different types of reinforced specimens: two layers to reinforce both surfaces (i), and one layer for only one surface (ii). The point of this (ii) is to respect the Italian legislation indications for the protection of historic constructions
TRM reinforcement of masonry specimens for seismic areas / Salvador, Ivorra; Bru Orts, David; Galvañ Morena, Antonio; Silvestri, Stefano; Apera, Cristina; Foti, Dora. - In: INTERNATIONAL JOURNAL OF SAFETY AND SECURITY ENGINEERING. - ISSN 2041-9031. - STAMPA. - 7:4(2017), pp. 463-474. [10.2495/SAFE-V7-N4-463-474]
TRM reinforcement of masonry specimens for seismic areas
Foti, Dora
2017-01-01
Abstract
This document analyses the resistant behaviour to diagonal compression and direct compression of brick masonry specimens, reinforced with textile reinforced mortars (TRM) and without them. The numerical models have been calibrated with experimental results in order to have a suitable technique to reinforce masonry historic constructions where extraordinary tension stresses could occur in seismic situations. For the numerical modelling, FEM models have been developed using non-linear layered bi-dimensional shell elements. Moreover, a comparative analysis has been developed between the numerical models and the experimental ones. There are two different types of reinforced specimens: two layers to reinforce both surfaces (i), and one layer for only one surface (ii). The point of this (ii) is to respect the Italian legislation indications for the protection of historic constructionsFile | Dimensione | Formato | |
---|---|---|---|
SSE070401f.pdf
accesso aperto
Tipologia:
Versione editoriale
Licenza:
Tutti i diritti riservati
Dimensione
2.91 MB
Formato
Adobe PDF
|
2.91 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.