The active detectors of the ALEPH hadron calorimeter at LEP consist of plastic streamer tubes developed in Frascati. The standard gas mixture for the operation of such devices is argon-isobutane ( 30 70). However, in underground experiments, for safety reasons, one has to reduce the hydrocarbon content. Therefore a study of the behaviour of streamer tubes operated with a Ar/CO2/n-pentane mixture has been performed. The influence of gas composition on efficiency, charge distribution and stability of operation has been investigated, and the results of these tests are presented.

Operation of limited streamer tubes with the gas mixture Ar + CO2 + n-pentane / Bagliesi, G.; Baldini-Celio, R.; Batignani, G.; Bencivenni, G.; Bologna, G. G.; Bossi, F.; Bottigli, U.; Bradaschia, C.; Campana, P.; Capon, G.; Catanesi, M. G.; Chiarella, V.; de Ninno, G.; de Palma, M.; D'Ettorre Piazzoli, B.; Dreucci, M.; Felici, G.; Foà, L.; Giassi, A.; Iaselli, G.; Laurelli, P.; Maggi, G.; Mannocchi, G.; Murtas, G. P.; Nicoletti, G.; Nuzzo, S.; Picchi, P.; Ranieri, A.; Raso, G.; Rigoni, H.; Romano, F.; Ruggieri, F.; Scapellato, S.; Selvaggi, G.; Tenchini, R.; Zito, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 268:1(1988), pp. 144-150. [10.1016/0168-9002(88)90599-2]

Operation of limited streamer tubes with the gas mixture Ar + CO2 + n-pentane

Iaselli, G.;Maggi, G.;
1988-01-01

Abstract

The active detectors of the ALEPH hadron calorimeter at LEP consist of plastic streamer tubes developed in Frascati. The standard gas mixture for the operation of such devices is argon-isobutane ( 30 70). However, in underground experiments, for safety reasons, one has to reduce the hydrocarbon content. Therefore a study of the behaviour of streamer tubes operated with a Ar/CO2/n-pentane mixture has been performed. The influence of gas composition on efficiency, charge distribution and stability of operation has been investigated, and the results of these tests are presented.
1988
Operation of limited streamer tubes with the gas mixture Ar + CO2 + n-pentane / Bagliesi, G.; Baldini-Celio, R.; Batignani, G.; Bencivenni, G.; Bologna, G. G.; Bossi, F.; Bottigli, U.; Bradaschia, C.; Campana, P.; Capon, G.; Catanesi, M. G.; Chiarella, V.; de Ninno, G.; de Palma, M.; D'Ettorre Piazzoli, B.; Dreucci, M.; Felici, G.; Foà, L.; Giassi, A.; Iaselli, G.; Laurelli, P.; Maggi, G.; Mannocchi, G.; Murtas, G. P.; Nicoletti, G.; Nuzzo, S.; Picchi, P.; Ranieri, A.; Raso, G.; Rigoni, H.; Romano, F.; Ruggieri, F.; Scapellato, S.; Selvaggi, G.; Tenchini, R.; Zito, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 268:1(1988), pp. 144-150. [10.1016/0168-9002(88)90599-2]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/1211
Citazioni
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact