Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
POLITECNICO DI BARI - Catalogo dei prodotti della Ricerca
This paper illustrates a method for the discrimination between πs and μs through the energy measurement and tracking capability of a hadron calorimeter followed by a system of chambers. Data taken in a test run with π and μ beams have been analyzed and compared with a sample indicated as π + μ. These π + μ events are obtained off line by taking one muon and one pion, superimposing their digital patterns and summing up their energy releases. The discriminant analysis employed provides a level of identification of about 99.5%. Such a result is very close to the physical limit corresponding to events with sail-through pions.
Pion muon identification in the aleph test hadron calorimeter using discriminant analysis / Baldini, R.; Batignani, G.; Bencivenni, G.; Bologna, G.; Bossi, F.; Bottigli, U.; Bradaschia, C.; Campana, P.; Capon, G.; Catanesi, M. G.; Chiarella, V.; de Palma, M.; D'Ettorre Piazzoli, B.; Felici, G.; Foa', L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Iaselli, G.; Laurelli, P.; Lin, J. F.; Maggi, G.; Mannocchi, G. P.; Murtas, G. P.; Natali, S.; Nicoletti, G.; Pallotta, M.; Picchi, P.; Raimondi, P.; Ranieri, A.; Romano, F.; Scapellato, S.; Selvaggi, G.; Triggiani, G.; Tupputi, R.; Zito, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 251:3(1986), pp. 449-456. [10.1016/0168-9002(86)90638-8]
Pion muon identification in the aleph test hadron calorimeter using discriminant analysis
Baldini, R.;Batignani, G.;Bencivenni, G.;Bologna, G.;Bossi, F.;Bottigli, U.;Bradaschia, C.;Campana, P.;Capon, G.;Catanesi, M. G.;Chiarella, V.;de Palma, M.;D'Ettorre Piazzoli, B.;Felici, G.;Foa', L.;Forti, F.;Giassi, A.;Giorgi, M. A.;Iaselli, G.;Laurelli, P.;Lin, J. F.;Maggi, G.;Mannocchi, G. P.;Murtas, G. P.;Natali, S.;Nicoletti, G.;Pallotta, M.;Picchi, P.;Raimondi, P.;Ranieri, A.;Romano, F.;Scapellato, S.;Selvaggi, G.;Triggiani, G.;Tupputi, R.;Zito, G.
1986-01-01
Abstract
This paper illustrates a method for the discrimination between πs and μs through the energy measurement and tracking capability of a hadron calorimeter followed by a system of chambers. Data taken in a test run with π and μ beams have been analyzed and compared with a sample indicated as π + μ. These π + μ events are obtained off line by taking one muon and one pion, superimposing their digital patterns and summing up their energy releases. The discriminant analysis employed provides a level of identification of about 99.5%. Such a result is very close to the physical limit corresponding to events with sail-through pions.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/1213
Citazioni
7
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.