Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
POLITECNICO DI BARI - Catalogo dei prodotti della Ricerca
We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small-angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics, use was made of Preshape32 Premux128 and VA1 chips. The signal-to-noise ratio and the resolution of the detectors was studied at different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.
Beam test results for single- and double-sided silicon detector prototypes of the CMS central detector / Adriani, O; Babucci, E; Bacchetta, N; Bagliesi, G; Bartalini, P; Basti, A; Bilei, Gm; Boemi, D; Borrello, L; Castaldi, R; Castellini, G; Catacchini, E; Cazzola, U; Checcucci, B; Civinini, C; Creanza, Donato Maria; Dalessandro, R; Depalma, M; Dellorso, R; Dellamarina, R; Fiore, L; Focardi, E; Gabbanini, A; Giassi, A; Giraldo, A; Gorn, L; Loreti, M; Maggi, Giorgio Pietro; Mantovani, G; Meschini, M; Messineo, A; My, S; Parrini, G; Pieri, M; Raffaelli, F; Raso, G; Santocchia, A; Selvaggi, G; Servoli, L; Silvestris, L; Skassyrskaia, A; Szoncso, F; Tempesta, P; Tesi, M; Tonelli, G; Vannini, C; Verdini, Pg; Wheadon, R.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 396:1-2(1997), pp. 76-92. [10.1016/S0168-9002(97)00750-X]
Beam test results for single- and double-sided silicon detector prototypes of the CMS central detector
We report the results of two beam tests performed in July and September 1995 at CERN using silicon microstrip detectors of various types: single sided, double sided with small-angle stereo strips, double sided with orthogonal strips, double sided with pads. For the read-out electronics, use was made of Preshape32 Premux128 and VA1 chips. The signal-to-noise ratio and the resolution of the detectors was studied at different incident angles of the incoming particles and for different values of the detector bias voltage. The goal of these tests was to check and improve the performances of the prototypes for the CMS Central Detector.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/157
Citazioni
11
9
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.