The paper discusses implementation issues related to the control of a three-phase grid-inverter for a windturbine system (WTS). The grid-side converter is controlled in order to maintain constant the DC voltage also in presence of grid voltage variations and the sinusoidal currents in phase with the corresponding voltages. PI and P+Resonat controllers are considered. For the P+Resonant controller different digital implementations are evaluated: Shift operator based and Delta operator based. A performance comparison, in terms of the C-code execution time is presented. The control algorithm based on PI controller has been experimentally verified.
Implementation on DSP TMS320F2812 of the Control of the Grid Converter of a Small Wind Turbine System / Nagliero, A; Liserre, Marco; Orlando, Na; Mastromauro, R; Dell’Aquila, A.. - (2009), pp. 415-419. (Intervento presentato al convegno ICCEP 2009 - 2nd International Conference on Clean Electrical Power Renewable Energy Resources Impac tenutosi a Capri (Italy) nel 9-11 Giugno 2009) [10.1109/ICCEP.2009.5212021].
Implementation on DSP TMS320F2812 of the Control of the Grid Converter of a Small Wind Turbine System
LISERRE, Marco;
2009-01-01
Abstract
The paper discusses implementation issues related to the control of a three-phase grid-inverter for a windturbine system (WTS). The grid-side converter is controlled in order to maintain constant the DC voltage also in presence of grid voltage variations and the sinusoidal currents in phase with the corresponding voltages. PI and P+Resonat controllers are considered. For the P+Resonant controller different digital implementations are evaluated: Shift operator based and Delta operator based. A performance comparison, in terms of the C-code execution time is presented. The control algorithm based on PI controller has been experimentally verified.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.