Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
POLITECNICO DI BARI - Catalogo dei prodotti della Ricerca
We present the results of two beam tests performed in July and September 1996 at CERN in order to study the behaviour of irradiated single- and double-sided silicon detectors from different manufacturers. All detectors had been irradiated with neutrons, up to a maximum fluence of 3.6 x 10(13) cm(-2), and had reached type inversion. Signal-to-noise ratio, resolution and efficiency have been studied for different values of detectors bias voltage, operation temperature (ranging from - 10 degrees C to f 20 degrees C) and read-out pitch and, in some case, for different incidence angle of the incoming particle. The results are promising, since no dramatic deterioration of detector performances has been observed. (C) 1998 Elsevier Science B.V. All rights reserved.
Beam test results for single- and double-sided irradiated silicon detector prototypes of the CMS Central Detector / Angarano, M., Azzi, P., Bacchetta, N., Bartalini, P., Bilei, G.M., Bisello, D., Boemi, D., Busetto, G., Castro, A., Checcucci, B., Creanza, D., Depalma, M., Fiore, L., Loreti, M., Martignon, G., My, S., Raso, G., Santocchia, A., Selvaggi, G., Servoli, L., et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 409:1-3(1998), pp. 135-138. [10.1016/S0168-9002(98)00082-5]
Beam test results for single- and double-sided irradiated silicon detector prototypes of the CMS Central Detector
We present the results of two beam tests performed in July and September 1996 at CERN in order to study the behaviour of irradiated single- and double-sided silicon detectors from different manufacturers. All detectors had been irradiated with neutrons, up to a maximum fluence of 3.6 x 10(13) cm(-2), and had reached type inversion. Signal-to-noise ratio, resolution and efficiency have been studied for different values of detectors bias voltage, operation temperature (ranging from - 10 degrees C to f 20 degrees C) and read-out pitch and, in some case, for different incidence angle of the incoming particle. The results are promising, since no dramatic deterioration of detector performances has been observed. (C) 1998 Elsevier Science B.V. All rights reserved.
Beam test results for single- and double-sided irradiated silicon detector prototypes of the CMS Central Detector / Angarano, M., Azzi, P., Bacchetta, N., Bartalini, P., Bilei, G.M., Bisello, D., Boemi, D., Busetto, G., Castro, A., Checcucci, B., Creanza, D., Depalma, M., Fiore, L., Loreti, M., Martignon, G., My, S., Raso, G., Santocchia, A., Selvaggi, G., Servoli, L., et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 409:1-3(1998), pp. 135-138. [10.1016/S0168-9002(98)00082-5]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/1636
Citazioni
1
2
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.