The design and realization of two highly sensitive and easily interchangeable spectrophones based on custom quartz tuning forks, with a rectangular (S1) or T-shaped (S2) prongs geometry, is reported. The two spectrophones have been implemented in a QEPAS sensor for ethylene detection, employing a DFB-QCL emitting at 10.337 μm with an optical power of 74.2 mW. A comparison between their performances showed a signal-to-noise ratio 3.4 times higher when implementing the S2 spectrophone. For the S2-based sensor, a linear dependence of the QEPAS signal on ethylene concentration was demonstrated in the 5 ppm −100 ppm range. For a 10 s lock-in integration time, an ethylene minimum detection limit of 10 ppb was calculated.

Quartz-enhanced photoacoustic sensor for ethylene detection implementing optimized custom tuning fork-based spectrophone / Giglio, Marilena; Elefante, Arianna; Patimisco, Pietro; Sampaolo, Angelo; Sgobba, Fabrizio; Rossmadl, Hubert; Mackowiak, Verena; Wu, Hongpeng; Tittel, Frank K.; Dong, Lei; Spagnolo, Vincenzo. - In: OPTICS EXPRESS. - ISSN 1094-4087. - ELETTRONICO. - 27:4(2019), pp. 4271-4280. [10.1364/OE.27.004271]

Quartz-enhanced photoacoustic sensor for ethylene detection implementing optimized custom tuning fork-based spectrophone

Giglio, Marilena;Patimisco, Pietro;Sampaolo, Angelo;Spagnolo, Vincenzo
2019-01-01

Abstract

The design and realization of two highly sensitive and easily interchangeable spectrophones based on custom quartz tuning forks, with a rectangular (S1) or T-shaped (S2) prongs geometry, is reported. The two spectrophones have been implemented in a QEPAS sensor for ethylene detection, employing a DFB-QCL emitting at 10.337 μm with an optical power of 74.2 mW. A comparison between their performances showed a signal-to-noise ratio 3.4 times higher when implementing the S2 spectrophone. For the S2-based sensor, a linear dependence of the QEPAS signal on ethylene concentration was demonstrated in the 5 ppm −100 ppm range. For a 10 s lock-in integration time, an ethylene minimum detection limit of 10 ppb was calculated.
2019
Quartz-enhanced photoacoustic sensor for ethylene detection implementing optimized custom tuning fork-based spectrophone / Giglio, Marilena; Elefante, Arianna; Patimisco, Pietro; Sampaolo, Angelo; Sgobba, Fabrizio; Rossmadl, Hubert; Mackowiak, Verena; Wu, Hongpeng; Tittel, Frank K.; Dong, Lei; Spagnolo, Vincenzo. - In: OPTICS EXPRESS. - ISSN 1094-4087. - ELETTRONICO. - 27:4(2019), pp. 4271-4280. [10.1364/OE.27.004271]
File in questo prodotto:
File Dimensione Formato  
103_QEPAS Ethylene_opex_2019.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione editoriale
Licenza: Tutti i diritti riservati
Dimensione 3.01 MB
Formato Adobe PDF
3.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/163889
Citazioni
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 49
social impact