A novel single-chip and multiplexed read-out circuit for multi-electrode electrochemical sensors, in standard 0.18 μm UMC CMOS technology, is presented. The circuit is a part of a fully-integrated biochip (in design) for the detection of multiple metabolites. The proposed topology is based on the potentiostat approach, and it is devoted to detect currents within the range of 250 pA - 650 nA for an electrode active area of 0.25 mm2. The need of multi-metabolites monitoring asks for a system with multi-working electrodes. In the proposed configuration, switches select one working electrode at each clock phase, while the others are short-circuited to the reference one, in order to nullify the injected current inside the counter. Low noise and low energy topology (50μW at 1.5V of voltage supply) is employed for the control amplifier. The linearity of the proposed read-out circuit allows accuracy better than 0.1%

A Novel Multi-Working Electrode Potentiostat for Electrochemical Detection of Metabolites / DE VENUTO, Daniela; Daniel Torre, M.; Boero, C.; Carrara, S.; De Micheli, G.. - (2010), pp. 1572-1577. (Intervento presentato al convegno IEEE Sensors 2010 Conference tenutosi a Waikoloa, Hi, USA nel November 1-4, 2010) [10.1109/ICSENS.2010.5690297].

A Novel Multi-Working Electrode Potentiostat for Electrochemical Detection of Metabolites

DE VENUTO, Daniela;
2010-01-01

Abstract

A novel single-chip and multiplexed read-out circuit for multi-electrode electrochemical sensors, in standard 0.18 μm UMC CMOS technology, is presented. The circuit is a part of a fully-integrated biochip (in design) for the detection of multiple metabolites. The proposed topology is based on the potentiostat approach, and it is devoted to detect currents within the range of 250 pA - 650 nA for an electrode active area of 0.25 mm2. The need of multi-metabolites monitoring asks for a system with multi-working electrodes. In the proposed configuration, switches select one working electrode at each clock phase, while the others are short-circuited to the reference one, in order to nullify the injected current inside the counter. Low noise and low energy topology (50μW at 1.5V of voltage supply) is employed for the control amplifier. The linearity of the proposed read-out circuit allows accuracy better than 0.1%
2010
IEEE Sensors 2010 Conference
978-1-4244-8170-5
A Novel Multi-Working Electrode Potentiostat for Electrochemical Detection of Metabolites / DE VENUTO, Daniela; Daniel Torre, M.; Boero, C.; Carrara, S.; De Micheli, G.. - (2010), pp. 1572-1577. (Intervento presentato al convegno IEEE Sensors 2010 Conference tenutosi a Waikoloa, Hi, USA nel November 1-4, 2010) [10.1109/ICSENS.2010.5690297].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/18784
Citazioni
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 27
social impact