Designing and manufacturing high-efficiency heat exchangers is usually considered a limiting factor in the development of gas turbines employing either heat recovery Joule-Brayton cycles or external combustion. In this work, an innovative heat exchanger is proposed, modeled, and partially tested to validate the developed numerical model employed for its design. The heat exchanger is based on an intermediate medium (aluminum oxide Al(2)O(3)) flowing in countercurrent through an hot stream of gas. In this process, heat can be absorbed from the hot gas, temporarily stored, and then similarly released in a second pipe, where a cold stream is warmed up. A flow of alumina particles with very small diameter (of the order of hundreds of microns) can be employed to enhance the heat transfer. Experimental tests demonstrate that simple one-dimensional steady equations, also neglecting conduction in the particles, can be effectively employed to simulate the flow in the vertical part of the pipe, namely, to compute the pipe length required to achieve a prescribed heat exchange. On the other side, full three-dimensional computational fluid dynamics simulations have been performed to demonstrate that a more thorough gas flow and particle displacement analysis is needed to avoid a bad distribution of alumina particles and, thus, to achieve high thermal efficiency.
An Immersed Particle Heat Exchanger for Externally Fired and Heat Recovery Gas Turbines / Catalano, L. A.; De Bellis, F.; Amirante, Riccardo; Rignanese, M.. - In: JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER. - ISSN 0742-4795. - 133:3(2011). [10.1115/1.4002157]
An Immersed Particle Heat Exchanger for Externally Fired and Heat Recovery Gas Turbines
AMIRANTE, Riccardo;
2011-01-01
Abstract
Designing and manufacturing high-efficiency heat exchangers is usually considered a limiting factor in the development of gas turbines employing either heat recovery Joule-Brayton cycles or external combustion. In this work, an innovative heat exchanger is proposed, modeled, and partially tested to validate the developed numerical model employed for its design. The heat exchanger is based on an intermediate medium (aluminum oxide Al(2)O(3)) flowing in countercurrent through an hot stream of gas. In this process, heat can be absorbed from the hot gas, temporarily stored, and then similarly released in a second pipe, where a cold stream is warmed up. A flow of alumina particles with very small diameter (of the order of hundreds of microns) can be employed to enhance the heat transfer. Experimental tests demonstrate that simple one-dimensional steady equations, also neglecting conduction in the particles, can be effectively employed to simulate the flow in the vertical part of the pipe, namely, to compute the pipe length required to achieve a prescribed heat exchange. On the other side, full three-dimensional computational fluid dynamics simulations have been performed to demonstrate that a more thorough gas flow and particle displacement analysis is needed to avoid a bad distribution of alumina particles and, thus, to achieve high thermal efficiency.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.