A room-temperature strip-guided “manufacturable” Silicon-on-Insulator (SOI)/GeSn integrated-photonics quantum-gyroscope chip operating at 1550 nm is proposed and analysed. We demonstrate how the entangled photons generated in Si Spontaneous Four Wave Mixing (SFWM) can be used to improve the resolution of a Sagnac interferometric gyroscope. We propose different integrated architectures based on degenerate and non-degenerate SFWM. The chip comprises several beam splitters, two SFWM entangled photon sources, a pump filter, integrated Mach–Zehnder interferometric gyro, and an array of waveguide coupled GeSn/Ge/Si single-photon avalanche detectors. The laser pumped SWFM sources generate the signal-idler pairs, which, in turn, are used to measure the two-photon, four-photon, and higher order coincidences, resulting in an increasing of the gyro resolution by a factor of two and four, with respect to the classical approach

On-Chip Group IV Heisenberg-Limited Sagnac Interferometric Gyroscope at Room Temperature / De Leonardis, Francesco; Soref, Richard; De Carlo, Martino; Passaro, Vittorio M. N.. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 20:12(2020). [10.3390/s20123476]

On-Chip Group IV Heisenberg-Limited Sagnac Interferometric Gyroscope at Room Temperature

Francesco De Leonardis
Membro del Collaboration Group
;
Martino De Carlo
Membro del Collaboration Group
;
Vittorio M. N. Passaro
Membro del Collaboration Group
2020-01-01

Abstract

A room-temperature strip-guided “manufacturable” Silicon-on-Insulator (SOI)/GeSn integrated-photonics quantum-gyroscope chip operating at 1550 nm is proposed and analysed. We demonstrate how the entangled photons generated in Si Spontaneous Four Wave Mixing (SFWM) can be used to improve the resolution of a Sagnac interferometric gyroscope. We propose different integrated architectures based on degenerate and non-degenerate SFWM. The chip comprises several beam splitters, two SFWM entangled photon sources, a pump filter, integrated Mach–Zehnder interferometric gyro, and an array of waveguide coupled GeSn/Ge/Si single-photon avalanche detectors. The laser pumped SWFM sources generate the signal-idler pairs, which, in turn, are used to measure the two-photon, four-photon, and higher order coincidences, resulting in an increasing of the gyro resolution by a factor of two and four, with respect to the classical approach
2020
On-Chip Group IV Heisenberg-Limited Sagnac Interferometric Gyroscope at Room Temperature / De Leonardis, Francesco; Soref, Richard; De Carlo, Martino; Passaro, Vittorio M. N.. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 20:12(2020). [10.3390/s20123476]
File in questo prodotto:
File Dimensione Formato  
sensors-20-03476-v2.pdf

accesso aperto

Descrizione: Articolo su Sensors
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 2.21 MB
Formato Adobe PDF
2.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/206738
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact