The construction of tunnels in urban areas inevitably entails the interaction with existing structures. While the effect of tunnel excavation on masonry structures has been thoroughly studied, the response of framed buildings has not been widely investigated in the past. In this paper, a parametric study of the response to tunnelling of reinforced concrete framed structures founded on strip footings is carried out using the Finite Element method. The foundations and the structural members of the building are modelled with a sufficient detail and a realistic contact law is employed to simulate the interaction between the foundation and the adjacent soil. Results are summarised in terms of deflection ratios and modification factors for horizontal strains. It is shown that the structural stiffness, mainly provided by the foundation, on average reduces the differential settlements and the horizontal displacements of the frame as compared to greenfield conditions. However, in contrast with what discussed in previously published papers, while the deflection ratio in sagging reduces as the number of floors becomes larger, it increases in hogging, which always occurs at the ends of the foundation. This evidence appears to be related to the non-uniform contact pressure at the soil-foundation interface and to the peculiar load distribution associated to the frame geometry.

Finite Element modelling of tunnelling-induced displacements on framed structures / Boldini, D.; Losacco, N.; Bertolin, S.; Amorosi, A.. - In: TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY. - ISSN 0886-7798. - STAMPA. - 80:(2018), pp. 222-231. [10.1016/j.tust.2018.06.019]

Finite Element modelling of tunnelling-induced displacements on framed structures

Losacco N.;
2018-01-01

Abstract

The construction of tunnels in urban areas inevitably entails the interaction with existing structures. While the effect of tunnel excavation on masonry structures has been thoroughly studied, the response of framed buildings has not been widely investigated in the past. In this paper, a parametric study of the response to tunnelling of reinforced concrete framed structures founded on strip footings is carried out using the Finite Element method. The foundations and the structural members of the building are modelled with a sufficient detail and a realistic contact law is employed to simulate the interaction between the foundation and the adjacent soil. Results are summarised in terms of deflection ratios and modification factors for horizontal strains. It is shown that the structural stiffness, mainly provided by the foundation, on average reduces the differential settlements and the horizontal displacements of the frame as compared to greenfield conditions. However, in contrast with what discussed in previously published papers, while the deflection ratio in sagging reduces as the number of floors becomes larger, it increases in hogging, which always occurs at the ends of the foundation. This evidence appears to be related to the non-uniform contact pressure at the soil-foundation interface and to the peculiar load distribution associated to the frame geometry.
2018
Finite Element modelling of tunnelling-induced displacements on framed structures / Boldini, D.; Losacco, N.; Bertolin, S.; Amorosi, A.. - In: TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY. - ISSN 0886-7798. - STAMPA. - 80:(2018), pp. 222-231. [10.1016/j.tust.2018.06.019]
File in questo prodotto:
File Dimensione Formato  
TUST_2017_426_Revision 2_V0_R2-mod.pdf

accesso aperto

Descrizione: Accepted manuscript
Tipologia: Documento in Post-print
Licenza: Creative commons
Dimensione 7.85 MB
Formato Adobe PDF
7.85 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/208618
Citazioni
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 56
social impact