This paper deals with a fundamental aspect in the control of grid-connected power converters, i.e., the detection of the positive-sequence component at fundamental frequency of the utility voltage under unbalanced and distorted conditions. Accurate and fast detection of this voltage component under grid faults is essential to keep the control over the power exchange with the grid avoiding to trip the converter protections and allowing the ride-through of the transient fault. In this paper, the systematic use of well known techniques conducts to a new positive-sequence voltage detection system which exhibits a fast, precise, and frequency-adaptive response under faulty grid conditions. Three fundamental functional blocks make up the proposed detector, these are: i) the quadrature-signals generator (QSG), ii) the positive-sequence calculator (PSC), and iii) the phase-locked loop (PLL). A key innovation of the proposed system is the use of a dual second order generalized integrator (DSOGI) to implement the QSG. For this reason, the proposed positive-sequence detector is called DSOGI-PLL. A detailed study of the DSOGI-PLL and verification by simulation are performed in this paper. From the obtained results, it can be concluded that the DSOGI-PLL is a very suitable technique for characterizing the positive-sequence voltage under grid faults.

New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions / Rodríguez, P.; Teodorescu, R.; Candela, I.; Timbus, A. V.; Liserre, M.; Blaabjerg, F.. - STAMPA. - (2006), pp. 692-698. (Intervento presentato al convegno 37th IEEE Power Electronics Specialists Conference 2006, PESC'06 tenutosi a Jeju, South Korea nel June 18-22, 2006) [10.1109/pesc.2006.1712059].

New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions

M. Liserre;
2006-01-01

Abstract

This paper deals with a fundamental aspect in the control of grid-connected power converters, i.e., the detection of the positive-sequence component at fundamental frequency of the utility voltage under unbalanced and distorted conditions. Accurate and fast detection of this voltage component under grid faults is essential to keep the control over the power exchange with the grid avoiding to trip the converter protections and allowing the ride-through of the transient fault. In this paper, the systematic use of well known techniques conducts to a new positive-sequence voltage detection system which exhibits a fast, precise, and frequency-adaptive response under faulty grid conditions. Three fundamental functional blocks make up the proposed detector, these are: i) the quadrature-signals generator (QSG), ii) the positive-sequence calculator (PSC), and iii) the phase-locked loop (PLL). A key innovation of the proposed system is the use of a dual second order generalized integrator (DSOGI) to implement the QSG. For this reason, the proposed positive-sequence detector is called DSOGI-PLL. A detailed study of the DSOGI-PLL and verification by simulation are performed in this paper. From the obtained results, it can be concluded that the DSOGI-PLL is a very suitable technique for characterizing the positive-sequence voltage under grid faults.
2006
37th IEEE Power Electronics Specialists Conference 2006, PESC'06
0-7803-9716-9
New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions / Rodríguez, P.; Teodorescu, R.; Candela, I.; Timbus, A. V.; Liserre, M.; Blaabjerg, F.. - STAMPA. - (2006), pp. 692-698. (Intervento presentato al convegno 37th IEEE Power Electronics Specialists Conference 2006, PESC'06 tenutosi a Jeju, South Korea nel June 18-22, 2006) [10.1109/pesc.2006.1712059].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/21079
Citazioni
  • Scopus 736
  • ???jsp.display-item.citation.isi??? 20
social impact