We report on a comparison between two optical detection techniques, one based on a Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detection module, where a quartz tuning fork is acoustically coupled with a pair of millimeter-sized resonator tubes; and the other one based on a Photothermal Spectroscopy (PTS) module where a Fabry-Perot interferometer acts as transducer to probe refractive index variations. When resonant optical absorption of modulated light occurs in a gas sample, QEPAS directly detects acoustic waves while PTS probes refractive index variations caused by local heating. Compact QEPAS and PTS detection modules were realized and integrated in a gas sensor system for detection of carbon monoxide (CO), targeting the fundamental band at 4.6 μm by using a distributed-feedback quantum cascade laser. Performance was compared and ultimate detection limits up to ~ 6 part-per-billion (ppb) and ~15 ppb were reached for QEPAS and the PTS module, respectively, using 100 s integration time and 40 mW of laser power.

Parts-per-billion detection of carbon monoxide: a comparison between quartz-enhanced photoacoustic and photothermal spectroscopy / Pinto, Davide; Moser, Harald; Waclawek, Johannes P.; Russo, Stefano Dello; Patimisco, Pietro; Spagnolo, Vincenzo; Lendl, Bernhard. - In: PHOTOACOUSTICS. - ISSN 2213-5979. - ELETTRONICO. - 22:(2021). [10.1016/j.pacs.2021.100244]

Parts-per-billion detection of carbon monoxide: a comparison between quartz-enhanced photoacoustic and photothermal spectroscopy

Patimisco, Pietro;Spagnolo, Vincenzo;
2021-01-01

Abstract

We report on a comparison between two optical detection techniques, one based on a Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detection module, where a quartz tuning fork is acoustically coupled with a pair of millimeter-sized resonator tubes; and the other one based on a Photothermal Spectroscopy (PTS) module where a Fabry-Perot interferometer acts as transducer to probe refractive index variations. When resonant optical absorption of modulated light occurs in a gas sample, QEPAS directly detects acoustic waves while PTS probes refractive index variations caused by local heating. Compact QEPAS and PTS detection modules were realized and integrated in a gas sensor system for detection of carbon monoxide (CO), targeting the fundamental band at 4.6 μm by using a distributed-feedback quantum cascade laser. Performance was compared and ultimate detection limits up to ~ 6 part-per-billion (ppb) and ~15 ppb were reached for QEPAS and the PTS module, respectively, using 100 s integration time and 40 mW of laser power.
2021
Parts-per-billion detection of carbon monoxide: a comparison between quartz-enhanced photoacoustic and photothermal spectroscopy / Pinto, Davide; Moser, Harald; Waclawek, Johannes P.; Russo, Stefano Dello; Patimisco, Pietro; Spagnolo, Vincenzo; Lendl, Bernhard. - In: PHOTOACOUSTICS. - ISSN 2213-5979. - ELETTRONICO. - 22:(2021). [10.1016/j.pacs.2021.100244]
File in questo prodotto:
File Dimensione Formato  
127_Ppb CO_QEPAS PTS_2021.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 4.13 MB
Formato Adobe PDF
4.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/217499
Citazioni
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 30
social impact