The analysis of forces, moments and pressure points has long been of great interest in orthodontics. Hence, we set out to define a method for measuring the pressure exerted by aligners on the teeth, and specifically to identify the precise points of pressure exertion. Intraoral scans were performed on a patient with optimal alignment and levelling before and after 2o vestibularisation of the upper central incisor. Pressure sensor film was placed in a dedicated housing between the aligner and teeth in order to record the pressure exerted after 15 s of aligner application. The images captured by the film were scanned, digitised, and subsequently analysed. Areas and amounts of pressure generated by the aligners were evaluated, and the net force of each was calculated, adjusted to take into consideration passive values. The method revealed the areas of contact by which the aligner transmits force on the teeth, and the pressures at which it does so. The pressure exerted by an aligner is not evenly distributed across the entire surface of the tooth during lingual tipping of an upper incisor. The areas of force concentration were not identical, as these are influenced by factors resulting from the manufacturing and casting processes.

Experimental study of the pressures and points of application of the forces exerted between aligner and tooth / Cervinara, Francesca; Cianci, Claudia; De Cillis, Francesco; Pappalettera, Giovanni; Pappalettere, Carmine; Siciliani, Giuseppe; Lombardo, Luca. - In: NANOMATERIALS. - ISSN 2079-4991. - ELETTRONICO. - 9:7(2019). [10.3390/nano9071010]

Experimental study of the pressures and points of application of the forces exerted between aligner and tooth

Claudia Cianci;Giovanni Pappalettera;Carmine Pappalettere;
2019-01-01

Abstract

The analysis of forces, moments and pressure points has long been of great interest in orthodontics. Hence, we set out to define a method for measuring the pressure exerted by aligners on the teeth, and specifically to identify the precise points of pressure exertion. Intraoral scans were performed on a patient with optimal alignment and levelling before and after 2o vestibularisation of the upper central incisor. Pressure sensor film was placed in a dedicated housing between the aligner and teeth in order to record the pressure exerted after 15 s of aligner application. The images captured by the film were scanned, digitised, and subsequently analysed. Areas and amounts of pressure generated by the aligners were evaluated, and the net force of each was calculated, adjusted to take into consideration passive values. The method revealed the areas of contact by which the aligner transmits force on the teeth, and the pressures at which it does so. The pressure exerted by an aligner is not evenly distributed across the entire surface of the tooth during lingual tipping of an upper incisor. The areas of force concentration were not identical, as these are influenced by factors resulting from the manufacturing and casting processes.
2019
Experimental study of the pressures and points of application of the forces exerted between aligner and tooth / Cervinara, Francesca; Cianci, Claudia; De Cillis, Francesco; Pappalettera, Giovanni; Pappalettere, Carmine; Siciliani, Giuseppe; Lombardo, Luca. - In: NANOMATERIALS. - ISSN 2079-4991. - ELETTRONICO. - 9:7(2019). [10.3390/nano9071010]
File in questo prodotto:
File Dimensione Formato  
nanomaterials-09-01010-v2.pdf

accesso aperto

Descrizione: Articolo Principale
Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 5.86 MB
Formato Adobe PDF
5.86 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/219900
Citazioni
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 17
social impact