This paper describes an integrated solution for an accurate DNA label-free detection. The sensor considered is capacitive and constists of two golden electrodes. A known DNA strands (probe) is immobilized over them and a capacitive shift occurs in presence of a complementary sequence inside the solution. The shift amount has been previously evaluated by means of a charge sensitive amplifier (CSA) with an active feedback resistance, followed by a comparator and a counter on a prototyping board. Starting from the measurement results an integrated version is presented here using a low-noise CSA to reduce the low-frequency noise and offset. The system provides an A/D conversion and an evaluation of the capacitive shift amount with a resolution of more than 12 bit. The proposed integrated version of the read-out demonstrates the ability to identify variation on the capacitive values of the sensor with a resolution of 0.1%

Design of an Integrated Low-Noise Read-Out System for DNA Capacitive Sensors / De Venuto, Daniela; Indiveri, Giancarlo; Valentini, Antonio. - STAMPA. - (2007). (Intervento presentato al convegno 2nd International Workshop on Advances in Sensors and Interface, IWASI 2007 tenutosi a Bari, Italy nel June 26-27, 2007) [10.1109/IWASI.2007.4420013].

Design of an Integrated Low-Noise Read-Out System for DNA Capacitive Sensors

Daniela De Venuto;
2007-01-01

Abstract

This paper describes an integrated solution for an accurate DNA label-free detection. The sensor considered is capacitive and constists of two golden electrodes. A known DNA strands (probe) is immobilized over them and a capacitive shift occurs in presence of a complementary sequence inside the solution. The shift amount has been previously evaluated by means of a charge sensitive amplifier (CSA) with an active feedback resistance, followed by a comparator and a counter on a prototyping board. Starting from the measurement results an integrated version is presented here using a low-noise CSA to reduce the low-frequency noise and offset. The system provides an A/D conversion and an evaluation of the capacitive shift amount with a resolution of more than 12 bit. The proposed integrated version of the read-out demonstrates the ability to identify variation on the capacitive values of the sensor with a resolution of 0.1%
2007
2nd International Workshop on Advances in Sensors and Interface, IWASI 2007
978-1-4244-1244-0
Design of an Integrated Low-Noise Read-Out System for DNA Capacitive Sensors / De Venuto, Daniela; Indiveri, Giancarlo; Valentini, Antonio. - STAMPA. - (2007). (Intervento presentato al convegno 2nd International Workshop on Advances in Sensors and Interface, IWASI 2007 tenutosi a Bari, Italy nel June 26-27, 2007) [10.1109/IWASI.2007.4420013].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/22087
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact