A sensor system for exhaled ammonia (NH3) monitoring exploiting quartz-enhanced photoacoustic spectroscopy (QEPAS) was demonstrated. An erbium-doped fiber amplifier (EDFA) with an operating frequency band targeting an NH3 absorption line falling at 1531.68 nm and capable to emit up to 3 W of optical power was employed. A custom T-shaped grooved QTF with prong spacing of 1 mm was designed and realized to allow a proper focusing of the high-power optical beam exiting the EDFA between the prongs. The performance of the realized sensor system was optimized in terms of spectrophone parameters, laser power and modulation current, resulting in a NH3 minimum detectable concentration of 14 ppb at 1 second averaging time, corresponding to a normalized noise equivalent absorption coefficient (NNEA) of 8.15 × 10-9 cm-1 W/√Hz. Continuous measurements of the NH3 level exhaled by 3 healthy volunteers was carried out to demonstrate the potentiality of the developed sensor for breath analysis applications.
Quartz-enhanced photoacoustic NH3 sensor exploiting a large-prong-spacing quartz tuning fork and an optical fiber amplifier for biomedical applications / Shang, Zhijin; Li, Shangzhi; Li, Biao; Wu, Hongpeng; Sampaolo, Angelo; Patimisco, Pietro; Spagnolo, Vincenzo; Dong, Lei. - In: PHOTOACOUSTICS. - ISSN 2213-5979. - ELETTRONICO. - 26:(2022). [10.1016/j.pacs.2022.100363]
Quartz-enhanced photoacoustic NH3 sensor exploiting a large-prong-spacing quartz tuning fork and an optical fiber amplifier for biomedical applications
Sampaolo, Angelo;Patimisco, Pietro;Spagnolo, Vincenzo;
2022-01-01
Abstract
A sensor system for exhaled ammonia (NH3) monitoring exploiting quartz-enhanced photoacoustic spectroscopy (QEPAS) was demonstrated. An erbium-doped fiber amplifier (EDFA) with an operating frequency band targeting an NH3 absorption line falling at 1531.68 nm and capable to emit up to 3 W of optical power was employed. A custom T-shaped grooved QTF with prong spacing of 1 mm was designed and realized to allow a proper focusing of the high-power optical beam exiting the EDFA between the prongs. The performance of the realized sensor system was optimized in terms of spectrophone parameters, laser power and modulation current, resulting in a NH3 minimum detectable concentration of 14 ppb at 1 second averaging time, corresponding to a normalized noise equivalent absorption coefficient (NNEA) of 8.15 × 10-9 cm-1 W/√Hz. Continuous measurements of the NH3 level exhaled by 3 healthy volunteers was carried out to demonstrate the potentiality of the developed sensor for breath analysis applications.File | Dimensione | Formato | |
---|---|---|---|
2022_Quartz-enhanced_photoacoustic_NH3_sensor_exploiting_a_large-prong-spacing_quartz_tuning_fork_pdfeditoriale.pdf