Supercritical carbon dioxide (sCO2) cycles are considered to provide a faster response to load change owing to their compact footprint. sCO2 cycles are generally highly recuperative, therefore the response time is mainly dictated by the heat exchanger characteristics. This study model the transient behaviour of a recuperator in 10 MWe simple recuperative Brayton cycle. The response for the variation of inlet temperature and mass flow boundary conditions were investigated using two approaches based on temperature and enthalpy. The performance of these two approaches are compared and the numerical schemes were discussed along with the challenges encountered. The simulation results were validated against the experimental data available in the literature with a fair agreement. The characteristic time of the heat exchanger for a step change of the boundary conditions is reported that supports the recuperator design process. Compact recuperator responded in less than 20 seconds for the changes in the temperature boundary condition whilst it can take upto 1.5 minutes for mass flow change. In order to reduce the computational effort, a logarithmic indexed lookup table approach is presented, reducing the simulation time by a factor of 20.

Recuperator transient simulation for supercritical carbon dioxide cycle in CSP applications / Thanganadar, D.; Fornarelli, Francesco; Camporeale, Sergio; Asfand, F.; Patchigolla, K.. - 11:(2020). [10.1115/GT2020-14785]

Recuperator transient simulation for supercritical carbon dioxide cycle in CSP applications

Fornarelli Francesco
Membro del Collaboration Group
;
Camporeale Sergio
Membro del Collaboration Group
;
2020-01-01

Abstract

Supercritical carbon dioxide (sCO2) cycles are considered to provide a faster response to load change owing to their compact footprint. sCO2 cycles are generally highly recuperative, therefore the response time is mainly dictated by the heat exchanger characteristics. This study model the transient behaviour of a recuperator in 10 MWe simple recuperative Brayton cycle. The response for the variation of inlet temperature and mass flow boundary conditions were investigated using two approaches based on temperature and enthalpy. The performance of these two approaches are compared and the numerical schemes were discussed along with the challenges encountered. The simulation results were validated against the experimental data available in the literature with a fair agreement. The characteristic time of the heat exchanger for a step change of the boundary conditions is reported that supports the recuperator design process. Compact recuperator responded in less than 20 seconds for the changes in the temperature boundary condition whilst it can take upto 1.5 minutes for mass flow change. In order to reduce the computational effort, a logarithmic indexed lookup table approach is presented, reducing the simulation time by a factor of 20.
2020
ASME Turbo Expo 2020: Turbomachinery Technical Conference and Exposition - Volume 11: Structures and Dynamics: Structural Mechanics, Vibration, and Damping; Supercritical CO2
978-0-7918-8423-2
Recuperator transient simulation for supercritical carbon dioxide cycle in CSP applications / Thanganadar, D.; Fornarelli, Francesco; Camporeale, Sergio; Asfand, F.; Patchigolla, K.. - 11:(2020). [10.1115/GT2020-14785]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/240681
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact