Photoacoustic spectroscopy (PAS) based gas sensors with high sensitivity, wide dynamic range, low cost, and small footprint are desirable in energy, environment, safety, and public health. However, most works have focused on either acoustic resonator to enhance acoustic wave or optical resonator to enhance optical wave. Herein, we develop a gas sensor based on doubly resonant PAS in which the acoustic and optical waves are simultaneously enhanced using combined optical and acoustic resonators in a centimeter-long configuration. Not only the lower detection limit is enhanced by the double standing waves, but also the upper detection limit is expanded due to the short resonators. As an example, we developed a sensor by detecting acetylene (C2H2), achieving a noise equivalent absorption of 5.7 × 10−13 cm−1 and a dynamic range of eight orders. Compared to the state-of-the-art PAS gas sensors, the developed sensor achieves a record sensitivity and dynamic range.

Doubly resonant sub-ppt photoacoustic gas detection with eight decades dynamic range / Wang, Zhen; Wang, Qiang; Zhang, Hui; Borri, Simone; Galli, Iacopo; Sampaolo, Angelo; Patimisco, Pietro; Spagnolo, Vincenzo Luigi; De Natale, Paolo; Ren, Wei. - In: PHOTOACOUSTICS. - ISSN 2213-5979. - ELETTRONICO. - 27:(2022). [10.1016/j.pacs.2022.100387]

Doubly resonant sub-ppt photoacoustic gas detection with eight decades dynamic range

Sampaolo, Angelo;Patimisco, Pietro;Spagnolo, Vincenzo Luigi;
2022-01-01

Abstract

Photoacoustic spectroscopy (PAS) based gas sensors with high sensitivity, wide dynamic range, low cost, and small footprint are desirable in energy, environment, safety, and public health. However, most works have focused on either acoustic resonator to enhance acoustic wave or optical resonator to enhance optical wave. Herein, we develop a gas sensor based on doubly resonant PAS in which the acoustic and optical waves are simultaneously enhanced using combined optical and acoustic resonators in a centimeter-long configuration. Not only the lower detection limit is enhanced by the double standing waves, but also the upper detection limit is expanded due to the short resonators. As an example, we developed a sensor by detecting acetylene (C2H2), achieving a noise equivalent absorption of 5.7 × 10−13 cm−1 and a dynamic range of eight orders. Compared to the state-of-the-art PAS gas sensors, the developed sensor achieves a record sensitivity and dynamic range.
2022
Doubly resonant sub-ppt photoacoustic gas detection with eight decades dynamic range / Wang, Zhen; Wang, Qiang; Zhang, Hui; Borri, Simone; Galli, Iacopo; Sampaolo, Angelo; Patimisco, Pietro; Spagnolo, Vincenzo Luigi; De Natale, Paolo; Ren, Wei. - In: PHOTOACOUSTICS. - ISSN 2213-5979. - ELETTRONICO. - 27:(2022). [10.1016/j.pacs.2022.100387]
File in questo prodotto:
File Dimensione Formato  
2022_Doubly_resonant_sub-ppt_photoacoustic_gas_detection_with_eight_decades_dynamic_range_pdfeditoriale.pdf

accesso aperto

Tipologia: Versione editoriale
Licenza: Creative commons
Dimensione 2.97 MB
Formato Adobe PDF
2.97 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/241800
Citazioni
  • Scopus 81
  • ???jsp.display-item.citation.isi??? 72
social impact