Several measurements have been made on different phototubes in order to select the type to be used for the readout system of the NOE magnetized scintillating fiber calorimeter. Characteristics Such as gain, linearity, time resolution and cathode uniformity have been examined on several PMT types with standard, fine mesh or channel multiplier structure. The PMT response in the presence of the magnetized calorimeter fringe fields has also been studied. Here we report on the results of these measurements and of the comparisons between the different PMT types.

Evaluation of candidate photomultiplier tubes for the NOE scintillating fiber calorimeter / Barbarino, G. C.; Bernardini, P.; Brigida, M.; Campana, D.; Candela, A.; Caruso, R.; Ceres, A.; De Mitri, I.; Di Credico, A.; Favuzzi, C.; Fusco, P.; Gargano, F.; Giglietto, N.; Giordano, F.; Grillo, A.; Guarino, F.; Leone, A.; Lindozzi, M.; Loparco, F.; Mancarella, G.; Mazziotta, M. N.; Mongelli, M.; Osteria, G.; Palladino, V.; Perchiazzi, M.; Pinto, C.; Rainò, A.; Rainò, S.; Sacchetti, A.; Scapparone, E.; Spinelli, P.; Zilli, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 483:3(2002), pp. 660-669. [10.1016/S0168-9002(01)01939-8]

Evaluation of candidate photomultiplier tubes for the NOE scintillating fiber calorimeter

Favuzzi, C.;Giglietto, N.;
2002-01-01

Abstract

Several measurements have been made on different phototubes in order to select the type to be used for the readout system of the NOE magnetized scintillating fiber calorimeter. Characteristics Such as gain, linearity, time resolution and cathode uniformity have been examined on several PMT types with standard, fine mesh or channel multiplier structure. The PMT response in the presence of the magnetized calorimeter fringe fields has also been studied. Here we report on the results of these measurements and of the comparisons between the different PMT types.
2002
Evaluation of candidate photomultiplier tubes for the NOE scintillating fiber calorimeter / Barbarino, G. C.; Bernardini, P.; Brigida, M.; Campana, D.; Candela, A.; Caruso, R.; Ceres, A.; De Mitri, I.; Di Credico, A.; Favuzzi, C.; Fusco, P.; Gargano, F.; Giglietto, N.; Giordano, F.; Grillo, A.; Guarino, F.; Leone, A.; Lindozzi, M.; Loparco, F.; Mancarella, G.; Mazziotta, M. N.; Mongelli, M.; Osteria, G.; Palladino, V.; Perchiazzi, M.; Pinto, C.; Rainò, A.; Rainò, S.; Sacchetti, A.; Scapparone, E.; Spinelli, P.; Zilli, A.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 483:3(2002), pp. 660-669. [10.1016/S0168-9002(01)01939-8]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/2444
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact