In order to give a tribute to the knowledge of the structural behaviour of pitched roof steel greenhouses a full scale load test was performed. Tests allowed to study elastic, elasto-plastic and collapse behaviour of the frame loaded by vertical and horizontal forces. The structure collapsed during the test mainly for the application of horizontal forces, when the failure of a upright caused instability and a change of the geometry of the frame. The results of the experimental tests represent the basis for the definition of the loading model.???

In order to give a tribute to the knowledge of the structural behaviour of pitched roof steel greenhouses a full scale load test was performed. Tests allowed to study elastic, elasto-plastic and collapse behaviour of the frame loaded by vertical and horizontal forces. The structure collapsed during the test mainly for the application of horizontal forces, when the failure of a upright caused instability and a change of the geometry of the frame. The results of the experimental tests represent the basis for the definition of the loading model.

Obiettivo della ricerca è investigare il meccanismo di collasso di una serra a navata. A tal fine sono state condotte una serie di prove di carico su una struttura portante di una serra a navata in modo da far pervenire al collasso il telaio attraverso una successione di carichi verticali e orizzontali, misurandone gli spostamenti e lo stato tensionale degli elementi strutturali. La serra è pervenuta al collasso, che è stato improvviso, con carichi prevalentemente orizzontali; il collasso è stato causato, probabilmente, dall’instabilità per carico di punta del montante superiore della capriata. I dati sperimentali costituiscono l’indispensabile base per la definizione del modello di calcolo delle strutture di serre a navata.

Prova a rottura di una struttura portante per serra a navata / Castellano, S.; SCARASCIA MUGNOZZA, Giacomo; Vox, Giuliano. - In: COLTURE PROTETTE. - ISSN 0390-0444. - STAMPA. - 35 (1):(2006), pp. 55-61.

Prova a rottura di una struttura portante per serra a navata

SCARASCIA MUGNOZZA, Giacomo;
2006-01-01

Abstract

In order to give a tribute to the knowledge of the structural behaviour of pitched roof steel greenhouses a full scale load test was performed. Tests allowed to study elastic, elasto-plastic and collapse behaviour of the frame loaded by vertical and horizontal forces. The structure collapsed during the test mainly for the application of horizontal forces, when the failure of a upright caused instability and a change of the geometry of the frame. The results of the experimental tests represent the basis for the definition of the loading model.
2006
Prova a rottura di una struttura portante per serra a navata / Castellano, S.; SCARASCIA MUGNOZZA, Giacomo; Vox, Giuliano. - In: COLTURE PROTETTE. - ISSN 0390-0444. - STAMPA. - 35 (1):(2006), pp. 55-61.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/250306
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact