This article presents a numeric comparative study of the inelastic structural response of base isolated buildings. The comparative study includes the following isolation systems: laminated rubber bearings, New Zealand one, pure friction and the frictional pendulum ones. The study is based on obtaining nonlinear response spectra for various design parameters using six earthquake records. Usually the base isolation of a new building seeks to maintain the structure in the linear elastic range. The response of old weak buildings or the response of new ones subjected to extreme earthquakes may not be, necessarily, in the aforementioned ideal elastic range. Consequently, it is important to characterize the response of isolated buildings responding inelastically. A conclusion from this research is that the isolators aect signicantly the structural response of weak systems. Rubber isolators seem slightly less sensitive to plastication that may occur in the structure compared to friction isolators. Ductility demands in the structure are aected signicantly by friction and neoprene protected systems, in particular sliding ones where larger demands are obtained.

Comparative study of the inelastic response of base isolated buildings / Ordonez, D.; Foti, D.; Bozzo, L.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 32:1(2003), pp. 151-164. [10.1002/eqe.224]

Comparative study of the inelastic response of base isolated buildings

Foti, D.;
2003-01-01

Abstract

This article presents a numeric comparative study of the inelastic structural response of base isolated buildings. The comparative study includes the following isolation systems: laminated rubber bearings, New Zealand one, pure friction and the frictional pendulum ones. The study is based on obtaining nonlinear response spectra for various design parameters using six earthquake records. Usually the base isolation of a new building seeks to maintain the structure in the linear elastic range. The response of old weak buildings or the response of new ones subjected to extreme earthquakes may not be, necessarily, in the aforementioned ideal elastic range. Consequently, it is important to characterize the response of isolated buildings responding inelastically. A conclusion from this research is that the isolators aect signicantly the structural response of weak systems. Rubber isolators seem slightly less sensitive to plastication that may occur in the structure compared to friction isolators. Ductility demands in the structure are aected signicantly by friction and neoprene protected systems, in particular sliding ones where larger demands are obtained.
2003
Comparative study of the inelastic response of base isolated buildings / Ordonez, D.; Foti, D.; Bozzo, L.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 32:1(2003), pp. 151-164. [10.1002/eqe.224]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/2605
Citazioni
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 51
social impact