Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
POLITECNICO DI BARI - Catalogo dei prodotti della Ricerca
We describe a search method for fast moving (beta = v/c > 5 x 10(-3)) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two-years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5 x 10(-15) cm(-2) s(-1) sr(-1) in the velocity range 5 x 10(-3) less than or equal to beta less than or equal to 0.99 and for nucleon decay catalysis cross-section smaller than similar to1 mb (C) 2002 Elsevier Science B.V. All rights reserved
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector / Ambrosio, M.; Antolini, R.; Auriemma, G.; Bakari, D.; Baldini, A.; Barbarino, G. C.; Barish, B. C.; Battistoni, G.; Becherini, Y.; Bellotti, R.; Bemporad, C.; Bernardini, P.; Bilokon, H.; Bloise, C.; Bower, C.; Brigida, M.; Bussino, S.; Cafagna, F.; Calicchio, M.; Campana, D.; Carboni, M.; Caruso, R.; Cecchini, S.; Cei, F.; Chiarella, V.; Choudhary, B. C.; Coutu, S.; De Cataldo, G.; Dekhissi, H.; De Marzo, C.; De Mitri, I.; Derkaoui, J.; De Vincenzi, M.; Dicredico, A.; Erriquez, O.; Favuzzi, C.; Forti, C.; Fusco, P.; Giacomelli, G.; Giannini, G.; Giglietto, N.; Giorgini, M.; Grassi, M.; Grillo, A.; Guarino, F.; Gustavino, C.; Habig, A.; Heinz, R.; Iarocci, E.; Katsavounidis, E.; Katsavounidis, I.; Kearns, E.; Kim, H.; Kyriazopoulou, S.; Lamanna, E.; Lane, C.; Levin, D. S.; Lipari, P.; Longley, N. P.; Longo, M. J.; Loparco, F.; Maaroufi, F.; Mancarella, G.; Mandrioli, G.; Manzoor, S.; Margiotta, A.; Marini, A.; Martello, D.; Marzari-Chiesa, A.; Mazziotta, M. N.; Michael, D. G.; Monacelli, P.; Montaruli, T.; Monteno, M.; Mufson, S.; Musser, J.; Nicolò, D.; Nolty, R.; Orth, C.; Osteria, G.; Palamara, O.; Patera, V.; Patrizii, L.; Pazzi, R.; Peck, C. W.; Perrone, L.; Petrera, S.; Popa, V.; Reynoldson, J.; Ronga, F.; Rrhioua, A.; Satriano, C.; Scapparone, E.; Scholberg, K.; Sciubba, A.; Serra, P.; Sioli, M.; Sirri, G.; Sitta, M.; Spinelli, P.; Spinetti, M.; Spurio, M.; Steinberg, R.; Stone, J. L.; Sulak, L. R.; Surdo, A.; Tarlè, G.; Togo, V.; Vakili, M.; Walter, C. W.; Webb, R.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - 18:1(2003), pp. 27-41. [10.1016/S0927-6505(01)00183-9]
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
Ambrosio, M.;Antolini, R.;Auriemma, G.;Bakari, D.;Baldini, A.;Barbarino, G. C.;Barish, B. C.;Battistoni, G.;Becherini, Y.;Bellotti, R.;Bemporad, C.;Bernardini, P.;Bilokon, H.;Bloise, C.;Bower, C.;Brigida, M.;Bussino, S.;Cafagna, F.;Calicchio, M.;Campana, D.;Carboni, M.;Caruso, R.;Cecchini, S.;Cei, F.;Chiarella, V.;Choudhary, B. C.;Coutu, S.;De Cataldo, G.;Dekhissi, H.;De Marzo, C.;De Mitri, I.;Derkaoui, J.;De Vincenzi, M.;DiCredico, A.;Erriquez, O.;Favuzzi, C.;Forti, C.;Fusco, P.;Giacomelli, G.;Giannini, G.;Giglietto, N.;Giorgini, M.;Grassi, M.;Grillo, A.;Guarino, F.;Gustavino, C.;Habig, A.;Heinz, R.;Iarocci, E.;Katsavounidis, E.;Katsavounidis, I.;Kearns, E.;Kim, H.;Kyriazopoulou, S.;Lamanna, E.;Lane, C.;Levin, D. S.;Lipari, P.;Longley, N. P.;Longo, M. J.;Loparco, F.;Maaroufi, F.;Mancarella, G.;Mandrioli, G.;Manzoor, S.;Margiotta, A.;Marini, A.;Martello, D.;Marzari-Chiesa, A.;Mazziotta, M. N.;Michael, D. G.;Monacelli, P.;Montaruli, T.;Monteno, M.;Mufson, S.;Musser, J.;Nicolò, D.;Nolty, R.;Orth, C.;Osteria, G.;Palamara, O.;Patera, V.;Patrizii, L.;Pazzi, R.;Peck, C. W.;Perrone, L.;Petrera, S.;Popa, V.;Reynoldson, J.;Ronga, F.;Rrhioua, A.;Satriano, C.;Scapparone, E.;Scholberg, K.;Sciubba, A.;Serra, P.;Sioli, M.;Sirri, G.;Sitta, M.;Spinelli, P.;Spinetti, M.;Spurio, M.;Steinberg, R.;Stone, J. L.;Sulak, L. R.;Surdo, A.;Tarlè, G.;Togo, V.;Vakili, M.;Walter, C. W.;Webb, R.
2003-01-01
Abstract
We describe a search method for fast moving (beta = v/c > 5 x 10(-3)) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two-years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5 x 10(-15) cm(-2) s(-1) sr(-1) in the velocity range 5 x 10(-3) less than or equal to beta less than or equal to 0.99 and for nucleon decay catalysis cross-section smaller than similar to1 mb (C) 2002 Elsevier Science B.V. All rights reserved
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/2639
Citazioni
7
12
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.