In this paper, an end-to-end methane gas detection algorithm based on transformer and multi-layer perceptron (MLP) for tunable diode laser absorption spectroscopy (TDLAS) is presented. It consists of a Transformer-based U-shaped Neural Network (TUNN) filtering algorithm and a concentration prediction network (CPN) based on MLP. This algorithm employs an end-to-end architectural design to extract information from noisy transmission spectra of methane and derive the CH4 concentrations from denoised spectra, without intermediate steps. The results demonstrate the superiority of the proposed TUNN filtering algorithm over other typically employed digital filters. For concentration prediction, the determination coefficient (R2) reached 99.7%. Even at low concentrations, R2 remained notably high, reaching up to 89%. The proposed algorithm results in a more efficient, convenient, and accurate spectral data processing for TDLAS-based gas sensors.

End-to-end methane gas detection algorithm based on transformer and multi-layer perceptron / Liu, Chang; Wang, Gang; Zhang, Chen; Patimisco, Pietro; Cui, Ruyue; Feng, Chaofan; Sampaolo, Angelo; Spagnolo, Vincenzo; Dong, Lei; Wu, Hongpeng. - In: OPTICS EXPRESS. - ISSN 1094-4087. - 32:1(2024), pp. 987-1002. [10.1364/OE.511813]

End-to-end methane gas detection algorithm based on transformer and multi-layer perceptron

Patimisco, Pietro;Sampaolo, Angelo;Spagnolo, Vincenzo;
2024-01-01

Abstract

In this paper, an end-to-end methane gas detection algorithm based on transformer and multi-layer perceptron (MLP) for tunable diode laser absorption spectroscopy (TDLAS) is presented. It consists of a Transformer-based U-shaped Neural Network (TUNN) filtering algorithm and a concentration prediction network (CPN) based on MLP. This algorithm employs an end-to-end architectural design to extract information from noisy transmission spectra of methane and derive the CH4 concentrations from denoised spectra, without intermediate steps. The results demonstrate the superiority of the proposed TUNN filtering algorithm over other typically employed digital filters. For concentration prediction, the determination coefficient (R2) reached 99.7%. Even at low concentrations, R2 remained notably high, reaching up to 89%. The proposed algorithm results in a more efficient, convenient, and accurate spectral data processing for TDLAS-based gas sensors.
2024
https://opg.optica.org/OE/abstract.cfm?uri=OE-32-1-987
End-to-end methane gas detection algorithm based on transformer and multi-layer perceptron / Liu, Chang; Wang, Gang; Zhang, Chen; Patimisco, Pietro; Cui, Ruyue; Feng, Chaofan; Sampaolo, Angelo; Spagnolo, Vincenzo; Dong, Lei; Wu, Hongpeng. - In: OPTICS EXPRESS. - ISSN 1094-4087. - 32:1(2024), pp. 987-1002. [10.1364/OE.511813]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/264187
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact