The study investigated the anti-correlation between thermal diffusivity and Ultimate Tensile Strength (UTS) in Usibor® 1500 steel. The non-destructive pulsed laser spot thermography technique was used to analyze fifteen boron steel specimens with varying bainite/martensite phase percentages, while the UTS was measured through uniaxial tensile tests. A 23 % thermal diffusivity difference was found between fully martensitic and fully bainitic structures, with UTS varying by around 90 %. The strong anti-correlation was confirmed (Spearman coefficient −0.98) and an empirical power-law equation was derived to estimate UTS based on thermal diffusivity variations. The approach showed an R-squared value over 0.84, providing a non-destructive thermographic procedure for UTS estimation in Usibor 1500 steel, offering valuable material property insights.
Non-destructive estimation of mechanical properties in Usibor® 1500 via thermal diffusivity measurements: A thermographic procedure / Dell’Avvocato, G.; Bison, P.; Palmieri, M. E.; Ferrarini, G.; Palumbo, D.; Tricarico, L.; Galietti, U.. - In: NDT & E INTERNATIONAL. - ISSN 0963-8695. - STAMPA. - 143:(2024). [10.1016/j.ndteint.2023.103034]
Non-destructive estimation of mechanical properties in Usibor® 1500 via thermal diffusivity measurements: A thermographic procedure
Dell’Avvocato, G.
;Palmieri, M. E.;Palumbo, D.;Tricarico, L.;Galietti, U.
2024-01-01
Abstract
The study investigated the anti-correlation between thermal diffusivity and Ultimate Tensile Strength (UTS) in Usibor® 1500 steel. The non-destructive pulsed laser spot thermography technique was used to analyze fifteen boron steel specimens with varying bainite/martensite phase percentages, while the UTS was measured through uniaxial tensile tests. A 23 % thermal diffusivity difference was found between fully martensitic and fully bainitic structures, with UTS varying by around 90 %. The strong anti-correlation was confirmed (Spearman coefficient −0.98) and an empirical power-law equation was derived to estimate UTS based on thermal diffusivity variations. The approach showed an R-squared value over 0.84, providing a non-destructive thermographic procedure for UTS estimation in Usibor 1500 steel, offering valuable material property insights.File | Dimensione | Formato | |
---|---|---|---|
2024_Non-destructiveestimationofmechanical_pdfeditoriale.pdf
accesso aperto
Tipologia:
Versione editoriale
Licenza:
Creative commons
Dimensione
9.44 MB
Formato
Adobe PDF
|
9.44 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.