The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7(th) of October 2021. During the magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. In order to reproduce the behavior, it was decided to conduct a dedicated test at the CERN North Area with the Goliath magnet, using four GE1/1 spare chambers. The test consisted in studying the characteristics of discharge events that occurred in different detector configurations and external conditions. Multiple magnetic field ramps were performed in sequence: patterns in the evolution of the discharge rates were observed with these data. The goal of this test is the understanding of the experimental conditions inducing discharges and short circuits in a GEM foil.The results of this test lead to the development of procedure for the optimal operation and performance of GEM detectors in the CMS experiment during the magnet ramps. Another important result is the estimation of the probability of short circuit generation, at 68 % confidence level, p(short)(HV OFF) = 0.42(-0.35)(+0.94)% with detector HV OFF and p(short)(HV OFF) < 0.49% with the HV ON. These numbers are specific for the detectors used during this test, but they provide a first quantitative indication on the phenomenon, and a point of comparison for future studies adopting the same procedure.
Impact of magnetic field on the stability of the CMS GE1/1 GEM detector operation / Abbas, M.; Abbott, S.; Abbrescia, M.; Abdalla, H.; Abdelalim, A.; Abuzeid, S.; Aebi, D.; Agapitos, A.; Ahmad, A.; Ahmed, A.; Ahmed, W.; Aimè, C.; Akhter, T.; Alsufyani, B.; Aruta, C.; Asghar, I.; Aspell, P.; Avila, C.; Babbar, J.; Ban, Y.; Band, R.; Bansal, S.; Benussi, L.; Bhatnagar, V.; Bianco, M.; Bianco, S.; Black, K.; Borgonovi, L.; Bouhali, O.; Braghieri, A.; Braibant, S.; Butalla, S.; Cagnotta, A.; Calzaferri, S.; Campagnola, R.; Caponero, M.; Carlson, J.; Cassese, F.; Cavallo, N.; Chauhan, S. S.; Choudhary, B.; Colafranceschi, S.; Colaleo, A.; Conde Garcia, A.; Datta, A.; De Iorio, A.; De Lentdecker, G.; Dell Olio, D.; De Robertis, G.; Dharmaratna, W.; Elkafrawy, T.; Erbacher, R.; Everaerts, P.; Fabozzi, F.; Fallavollita, F.; Fiorina, D.; Franco, M.; Galloni, C.; Giacomelli, P.; Gigli, S.; Gilmore, J.; Gola, M.; Gutierrez, A.; Hadjiiska, R.; Hoepfner, K.; Hohlmann, M.; Hong, Y.; Hoorani, H.; Huang, T.; Iaydjiev, P.; Irshad, A.; Iorio, A.; Ivone, F.; Jang, W.; Jaramillo, J.; Jeong, Y.; Juska, E.; Kailasapathy, B.; Kamon, T.; Kang, Y.; Karchin, P.; Kaur, A.; Kaur, H.; Keller, H.; Kim, H.; Kim, J.; Kim, M.; Kim, S.; Ko, B.; Kumar, A.; Kumar, S.; Lacalamita, N.; Lee, J. S. H.; Levin, A.; Li, Q.; Licciulli, F.; Lista, L.; Liyanage, K.; Loddo, F.; Luhach, M.; Maggi, M.; Maghrbi, Y.; Majumdar, N.; Malagalage, K.; Martiradonna, S.; Merlin, J.; Misheva, M.; Mocellin, G.; Moureaux, L.; Muhammad, A.; Muhammad, S.; Mukhopadhyay, S.; Naimuddin, M.; Nuzzo, S.; Oliveira, R.; Paolucci, P.; Park, I. C.; Passamonti, L.; Passeggio, G.; Peck, A.; Pellecchia, A.; Perera, N.; Petre, L.; Piccolo, D.; Pierluigi, D.; Radogna, R.; Raffone, G.; Ramirez, F.; Ranieri, A.; Rashevski, G.; Rathjens, D.; Regnery, B.; Rendon, C.; Riccardi, C.; Rossi, B.; Rout, P.; Ruiz, J. D.; Russo, A.; Safonov, A.; Sahota, A. K.; Saltzberg, D.; Saviano, G.; Shah, A.; Sharma, A.; Sharma, R.; Sheokand, T.; Shopova, M.; Simone, F.; Singh, J.; Sonnadara, U.; Sturdy, J.; Sultanov, G.; Szillasi, Z.; Teague, D.; Teyssier, D.; Tytgat, M.; Vai, I.; Vanegas, N.; Venditti, R.; Verwilligen, P.; Vetens, W.; Virdi, A. K.; Vitulo, P.; Wajid, A.; Wang, D.; Wang, K.; Watson, I. J.; Wickramage, N.; Wickramarathna, D. D. C.; Yanes, E.; Yang, S.; Yang, U.; Yang, Y.; Yoon, I.; You, Z.; Yu, I.; Zaleski, S.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 18:11(2023). [10.1088/1748-0221/18/11/p11029]
Impact of magnetic field on the stability of the CMS GE1/1 GEM detector operation
The Gas Electron Multiplier (GEM) detectors of the GE1/1 station of the CMS experiment have been operated in the CMS magnetic field for the first time on the 7(th) of October 2021. During the magnetic field ramps, several discharge phenomena were observed, leading to instability in the GEM High Voltage (HV) power system. In order to reproduce the behavior, it was decided to conduct a dedicated test at the CERN North Area with the Goliath magnet, using four GE1/1 spare chambers. The test consisted in studying the characteristics of discharge events that occurred in different detector configurations and external conditions. Multiple magnetic field ramps were performed in sequence: patterns in the evolution of the discharge rates were observed with these data. The goal of this test is the understanding of the experimental conditions inducing discharges and short circuits in a GEM foil.The results of this test lead to the development of procedure for the optimal operation and performance of GEM detectors in the CMS experiment during the magnet ramps. Another important result is the estimation of the probability of short circuit generation, at 68 % confidence level, p(short)(HV OFF) = 0.42(-0.35)(+0.94)% with detector HV OFF and p(short)(HV OFF) < 0.49% with the HV ON. These numbers are specific for the detectors used during this test, but they provide a first quantitative indication on the phenomenon, and a point of comparison for future studies adopting the same procedure.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/276823
Citazioni
1
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.