The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1cm from the beam pipe, and at 14.4m from the CMS interaction point, covering the pseudorapidity range of -6.6 < η < -5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC.

The very forward CASTOR calorimeter of the CMS experiment / Khachatryan, V., Sirunyan, A.M., Tumasyan, A., Adam, W., Ambrogi, F., Bergauer, T., Dragicevic, M., Ero, J., Escalante Del Valle, A., Fruhwirth, R., Jeitler, M., Krammer, N., Lechner, L., Liko, D., Madlener, T., Mikulec, I., Pitters, F.M., Rad, N., Schieck, J., Schofbeck, R., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 16:2(2021). [10.1088/1748-0221/16/02/P02010]

The very forward CASTOR calorimeter of the CMS experiment

Creanza D.;De Filippis N.;Iaselli G.;Pugliese G.;Simone F. M.;
2021

Abstract

The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1cm from the beam pipe, and at 14.4m from the CMS interaction point, covering the pseudorapidity range of -6.6 < η < -5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets, and processes characterized by rapidity gaps, is reviewed using data collected in proton and nuclear collisions at the LHC.
2021
The very forward CASTOR calorimeter of the CMS experiment / Khachatryan, V., Sirunyan, A.M., Tumasyan, A., Adam, W., Ambrogi, F., Bergauer, T., Dragicevic, M., Ero, J., Escalante Del Valle, A., Fruhwirth, R., Jeitler, M., Krammer, N., Lechner, L., Liko, D., Madlener, T., Mikulec, I., Pitters, F.M., Rad, N., Schieck, J., Schofbeck, R., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 16:2(2021). [10.1088/1748-0221/16/02/P02010]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/277065
Citazioni
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 12
social impact