A set of commercial triaxial micro-electromechanical systems (MEMS) accelerometers was calibrated using a custom-designed test bench featuring a rotating table. The calibration setup enabled simultaneous assessment of all accelerometer measurement components, generating precise reference accelerations within a frequency range of 0 to 8 Hz. A working model of the calibration setup and procedure was described to provide a complete uncertainty budget for both the reference and sensor accelerations. Through experimental uncertainty assessment of all the accelerometers, linearity and sensitivity were evaluated at different sensor levels. These parameters were determined by considering a single value for each accelerometer and detailing the analysis for each axis. Data processing revealed the achievable level of uncertainty and how it was influenced by the evaluation method employed for analyzing the calibration data.
Dynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment / Chiominto, Luciano; D'Emilia, Giulio; Gaspari, Antonella; Natale, Emanuela. - In: SENSORS. - ISSN 1424-8220. - ELETTRONICO. - 25:7(2025). [10.3390/s25072120]
Dynamic Multi-Axis Calibration of MEMS Accelerometers for Sensitivity and Linearity Assessment
Gaspari, Antonella;
2025
Abstract
A set of commercial triaxial micro-electromechanical systems (MEMS) accelerometers was calibrated using a custom-designed test bench featuring a rotating table. The calibration setup enabled simultaneous assessment of all accelerometer measurement components, generating precise reference accelerations within a frequency range of 0 to 8 Hz. A working model of the calibration setup and procedure was described to provide a complete uncertainty budget for both the reference and sensor accelerations. Through experimental uncertainty assessment of all the accelerometers, linearity and sensitivity were evaluated at different sensor levels. These parameters were determined by considering a single value for each accelerometer and detailing the analysis for each axis. Data processing revealed the achievable level of uncertainty and how it was influenced by the evaluation method employed for analyzing the calibration data.File | Dimensione | Formato | |
---|---|---|---|
2025_Dynamic_Multi-Axis_Calibration_of_MEMS_Accelerometers_for_Sensitivity_and_Linearity_Assessment_pdfeditoriale.pdf
accesso aperto
Tipologia:
Versione editoriale
Licenza:
Creative commons
Dimensione
4.19 MB
Formato
Adobe PDF
|
4.19 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.