Simultaneous detection of multiple gases with concentrations spanning five to six orders of magnitude remains a significant challenge for conventional sensing technologies. In this work, we present a dual-spectral (QEPAS-LITES) multi-gas detection system based on a single customized quartz tuning fork (QTF). By applying second-harmonic (2 f) wavelength modulation at 1368.6 nm and 1653.7 nm, the fundamental and first-overtone resonance modes of the QTF are excited concurrently, enabling intrinsic frequency-domain separation and parallel demodulation of photoacoustic and photothermal signals. This streamlined architecture enables truly simultaneous monitoring of percent-level H2O and ppm-level CH4, effectively overcoming the dynamic-range limitations of standard multi-gas sensing. Excellent linearity is obtained for both species (R² = 0.9999 for H₂O and 0.998 for CH₄), with minimum detection limits of approximately 30 ppm and 660 ppb, respectively. Allan-Werle deviation analysis confirms stable long-term operation for both detection channels. By overcoming the dynamic-range and saturation limitations of conventional multi-gas sensors, the proposed dual-mode approach provides a robust and scalable platform for wide-dynamic-range gas sensing in applications including atmospheric greenhouse gas monitoring, industrial emission analysis, and complex open-path environments.
Overcoming dynamic-range limitations in dual-gas sensing via dual-mode QTF excitation / Shen, Xiaowen; Sun, Chaofeng; Patimisco, Pietro; Sampaolo, Angelo; Spagnolo, Vincenzo; Dong, Lei; Wu, Hongpeng. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - ELETTRONICO. - 462:(2026). [10.1016/j.snb.2026.140001]
Overcoming dynamic-range limitations in dual-gas sensing via dual-mode QTF excitation
Shen, Xiaowen;Patimisco, Pietro;Sampaolo, Angelo;Spagnolo, Vincenzo;Dong, Lei;Wu, Hongpeng
2026
Abstract
Simultaneous detection of multiple gases with concentrations spanning five to six orders of magnitude remains a significant challenge for conventional sensing technologies. In this work, we present a dual-spectral (QEPAS-LITES) multi-gas detection system based on a single customized quartz tuning fork (QTF). By applying second-harmonic (2 f) wavelength modulation at 1368.6 nm and 1653.7 nm, the fundamental and first-overtone resonance modes of the QTF are excited concurrently, enabling intrinsic frequency-domain separation and parallel demodulation of photoacoustic and photothermal signals. This streamlined architecture enables truly simultaneous monitoring of percent-level H2O and ppm-level CH4, effectively overcoming the dynamic-range limitations of standard multi-gas sensing. Excellent linearity is obtained for both species (R² = 0.9999 for H₂O and 0.998 for CH₄), with minimum detection limits of approximately 30 ppm and 660 ppb, respectively. Allan-Werle deviation analysis confirms stable long-term operation for both detection channels. By overcoming the dynamic-range and saturation limitations of conventional multi-gas sensors, the proposed dual-mode approach provides a robust and scalable platform for wide-dynamic-range gas sensing in applications including atmospheric greenhouse gas monitoring, industrial emission analysis, and complex open-path environments.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.