Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
POLITECNICO DI BARI - Catalogo dei prodotti della Ricerca
The paper describes the Silicon Tracking System of the Compact Muon Solenoid (CMS) experiment that is foreseen to collect events from p-p collision at the E-cm = 14 TeV at the CERN future Large Hadron Collider (LHC). The proposed system consists of four layers of silicon microstrip detectors placed between the two inner layers of the pixel detector and the outer microstrip gas chamber system. The barrel part covers the eta region up to 1.8, instrumenting the central radial region between 20 and 50 cm. The forward-backward disks extend the coverage up to eta = 2.6. This paper will review the main characteristics and performances of the system, the actual status of the R&D activities that we are carrying on, and the status of the milestones we have to fulfill in view of the Technical Design Report expected at the end of the year
The CMS silicon tracker at LHC / Bilei, Gm; Albergo, S; Angarano, M; Azzi, P; Bacchetta, N; Bagliesi, G; Bartalini, P; Basti, A; Biggeri, U; Bisello, D; Boemi, D; Cazzola, U; Borrello, L; Bozzi, C; Breuker, H; Bruzzi, M; Candelori, A; Caner, A; Castaldi, R; Catacchini, E; Checcucci, B; Ciampolini, P; Ciasnohova, A; Civinini, C; Connotte, J; Creanza, Donato Maria; D'Alessandro, R; Da Rold, M; de Palma, M; Dell'Orso, R; Della Marina, R; Eklund, C; Elliott Peisert, A; Fiore, L; Focardi, E; French, M; Giassi, A; Giraldo, A; Glessing, B; Gu, Wh; Hall, G; Hammerstrom, R; Hrubec, J; Huhtinen, M; Karimaki, V; Krammer, M; Lariccia, P; Loreti, M; Luebelsmeyer, K; Lustermann, W; Maggi, Giorgio Pietro; Mannelli, M; Mantovani, G; Marchioro, A; Martignon, G; Mc Evoy, B; Meschini, M; Messineo, A; My, S; Paccagnella, A; Pandoulas, D; Parrini, G; Passeri, D; Pieri, M; Potenza, R; Raffaelli, F; Raso, G; Raymond, M; Santocchia, A; Schmitt, B; Selvaggi, G; Servoli, L; Siedling, R; Silvestris, L; Skassyrskaia, A; Skog, K; Starodumov, A; Stavitsky, I; Stefanini, G; Tempesta, P; Tonelli, G; Tricomi, A; Tuuva, T; Vannini, C; Verdini, Pg; Viertel, G; Xie, Z; Watts, S; Wittmer, B.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 409:1-3(1998), pp. 105-111. [10.1016/S0168-9002(97)01247-3]
The paper describes the Silicon Tracking System of the Compact Muon Solenoid (CMS) experiment that is foreseen to collect events from p-p collision at the E-cm = 14 TeV at the CERN future Large Hadron Collider (LHC). The proposed system consists of four layers of silicon microstrip detectors placed between the two inner layers of the pixel detector and the outer microstrip gas chamber system. The barrel part covers the eta region up to 1.8, instrumenting the central radial region between 20 and 50 cm. The forward-backward disks extend the coverage up to eta = 2.6. This paper will review the main characteristics and performances of the system, the actual status of the R&D activities that we are carrying on, and the status of the milestones we have to fulfill in view of the Technical Design Report expected at the end of the year
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/3029
Citazioni
0
0
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.