Ground heat exchangers are key components of shallow geothermal systems, including ground-coupled heat pumps and underground thermal energy storage systems. Reducing their installation costs through innovative designs remains a major challenge. In this study, the thermal performance of a Novel groundwater-filled Ground Heat Exchanger (NGHE) designed to promote thermally induced natural convection is investigated. The system incorporates truncated conical heat exchange plates, which increase the effective heat transfer surface area per unit depth and enhance thermally induced convective flow. A numerical model is developed and validated using experimental data to assess the behavior of this new design at shallow subsurface installation depths (i.e. 3–9 m below basement level). Three installation configurations have been proposed and analyzed. A comprehensive set of simulations is carried out to quantify the influence of key design parameters, installation geometry, and subsurface hydrogeological conditions. The metropolitan area of Bari (Italy) is used as a climate and hydrogeological framework. Results indicate that the novel ground heat exchanger is more efficient than the Conventional Ground Heat Exchanger (CGHE) design under a wide range of installation configurations, hydrogeological conditions, and operating modes. These findings suggest that the proposed heat exchanger could enable more compact and cost-effective shallow geothermal systems.
Numerical investigations of the thermal performance of a novel groundwater – filled ground heat exchanger design / Pastore, N., Giasi, C.I.. - In: RENEWABLE ENERGY. - ISSN 0960-1481. - 276:(2026), pp. 126369.126369-126369.126369. [10.1016/j.renene.2026.126369]
Numerical investigations of the thermal performance of a novel groundwater – filled ground heat exchanger design
Pastore N.
;Giasi C. I.
2026
Abstract
Ground heat exchangers are key components of shallow geothermal systems, including ground-coupled heat pumps and underground thermal energy storage systems. Reducing their installation costs through innovative designs remains a major challenge. In this study, the thermal performance of a Novel groundwater-filled Ground Heat Exchanger (NGHE) designed to promote thermally induced natural convection is investigated. The system incorporates truncated conical heat exchange plates, which increase the effective heat transfer surface area per unit depth and enhance thermally induced convective flow. A numerical model is developed and validated using experimental data to assess the behavior of this new design at shallow subsurface installation depths (i.e. 3–9 m below basement level). Three installation configurations have been proposed and analyzed. A comprehensive set of simulations is carried out to quantify the influence of key design parameters, installation geometry, and subsurface hydrogeological conditions. The metropolitan area of Bari (Italy) is used as a climate and hydrogeological framework. Results indicate that the novel ground heat exchanger is more efficient than the Conventional Ground Heat Exchanger (CGHE) design under a wide range of installation configurations, hydrogeological conditions, and operating modes. These findings suggest that the proposed heat exchanger could enable more compact and cost-effective shallow geothermal systems.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.