Sulfur hexafluoride (SF6) leakage monitoring is essential for the reliable operation of high-voltage equipment. However, conventional absorption-spectroscopy approaches typically require mid-infrared sources because SF6 exhibits its strongest fundamental absorption band near 10.54 μm, which increases system complexity and cost. Here, we propose an optical-source-free SF6 sensing method based on the transient response of a quartz tuning fork (QTF). The method exploits concentration-dependent changes in gas damping and added mass to retrieve the QTF resonance frequency and Q-factor in real time from an electrically excited transient beat signal. Experiments performed under different pressure conditions show that both the reciprocal Q-factor and the resonance frequency exhibit strong linear correlations with SF6 concentration from 0 % to 10 %. The highest sensitivity is obtained at 700 Torr. With a modulation frequency of 12457.3 Hz and a lock-in time constant of 3 ms, the system achieves a detection limit of 0.3 % within a 2.5 s measurement time. This approach provides a simple, low-cost, and rapid alternative for sub-percent SF6 leakage monitoring and may be extended to other gases with weak accessible absorption features or large density contrasts relative to the background gas.

Rapid and Wide-Range SF6 Leakage Monitoring for High-Voltage Equipment Exploiting QTF Transient Behavior / Yang, X., Zhang, D., Liang, Y., Xu, K., Spagnolo, V., Yin, X.. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - ELETTRONICO. - 26:21(2026), pp. 32227-32233. [10.1109/jsen.2026.3733080]

Rapid and Wide-Range SF6 Leakage Monitoring for High-Voltage Equipment Exploiting QTF Transient Behavior

Spagnolo, Vincenzo;
2026

Abstract

Sulfur hexafluoride (SF6) leakage monitoring is essential for the reliable operation of high-voltage equipment. However, conventional absorption-spectroscopy approaches typically require mid-infrared sources because SF6 exhibits its strongest fundamental absorption band near 10.54 μm, which increases system complexity and cost. Here, we propose an optical-source-free SF6 sensing method based on the transient response of a quartz tuning fork (QTF). The method exploits concentration-dependent changes in gas damping and added mass to retrieve the QTF resonance frequency and Q-factor in real time from an electrically excited transient beat signal. Experiments performed under different pressure conditions show that both the reciprocal Q-factor and the resonance frequency exhibit strong linear correlations with SF6 concentration from 0 % to 10 %. The highest sensitivity is obtained at 700 Torr. With a modulation frequency of 12457.3 Hz and a lock-in time constant of 3 ms, the system achieves a detection limit of 0.3 % within a 2.5 s measurement time. This approach provides a simple, low-cost, and rapid alternative for sub-percent SF6 leakage monitoring and may be extended to other gases with weak accessible absorption features or large density contrasts relative to the background gas.
2026
https://ieeexplore.ieee.org/document/11703937
Rapid and Wide-Range SF6 Leakage Monitoring for High-Voltage Equipment Exploiting QTF Transient Behavior / Yang, X., Zhang, D., Liang, Y., Xu, K., Spagnolo, V., Yin, X.. - In: IEEE SENSORS JOURNAL. - ISSN 1530-437X. - ELETTRONICO. - 26:21(2026), pp. 32227-32233. [10.1109/jsen.2026.3733080]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/309700
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 1
social impact