The following research presents the numerical and experimental results obtained on a reduced scale steel model of a medium-rise building structure dynamically protected with energy dissipaters. The steel-steel friction dissipates energy as the structure undergoes interstory drifts. A preliminary numerical analysis is performed to determine the best position of the friction dampers in the longitudinal frames. All the nodes of the numerical model have been assumed with the same bending stiffness. Shaking table tests have been performed, both in random vibration tests (to determine the natural periods and the dynamic characteristics of the model) and in earthquake simulation tests (to study the dynamic behaviour of the model with and without dampers). The results have been compared to those achieved during a previous experimental study based on the same model protected with only one friction damper for each longitudinal frame.

On the Optimum Placement of Dissipators in a Steel Model Building Subjected to Shaking-Table Tests / Foti, Dora. - In: THE OPEN CONSTRUCTION & BUILDING TECHNOLOGY JOURNAL. - ISSN 1874-8368. - 8:(2014), pp. 142-152. [10.2174/1874836801408010142]

On the Optimum Placement of Dissipators in a Steel Model Building Subjected to Shaking-Table Tests

FOTI, Dora
2014-01-01

Abstract

The following research presents the numerical and experimental results obtained on a reduced scale steel model of a medium-rise building structure dynamically protected with energy dissipaters. The steel-steel friction dissipates energy as the structure undergoes interstory drifts. A preliminary numerical analysis is performed to determine the best position of the friction dampers in the longitudinal frames. All the nodes of the numerical model have been assumed with the same bending stiffness. Shaking table tests have been performed, both in random vibration tests (to determine the natural periods and the dynamic characteristics of the model) and in earthquake simulation tests (to study the dynamic behaviour of the model with and without dampers). The results have been compared to those achieved during a previous experimental study based on the same model protected with only one friction damper for each longitudinal frame.
2014
On the Optimum Placement of Dissipators in a Steel Model Building Subjected to Shaking-Table Tests / Foti, Dora. - In: THE OPEN CONSTRUCTION & BUILDING TECHNOLOGY JOURNAL. - ISSN 1874-8368. - 8:(2014), pp. 142-152. [10.2174/1874836801408010142]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/3230
Citazioni
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact