Current standards provide a method for calculating the hygrometric performance of a multilayered wall (UNI 10350) that adopts simplified hypotheses that do not take into account important aspects like the dynamics of capillary adsorption. The value of the global resistance to the transmission of vapour, to be used in the control, is currently assessed using the permeability value supplied by UNI 10351, regardless of the geometry of the block and the type of structural brick. Within the framework of the Progetto Finalizzato MSTA2 from CNR, Bari Polytechnic carried out a series of measurements of the permeability to steam of walls made of plastered hollow blocks. The test, conducted on four types of walls with normal structural bricks and light weight ones, demonstrated little sensitivity to the resistance to the diffusion of water vapour with a variation of the vapour pressure or its gradient. What emerged was the importance of the permeability to water vapour of the brick with respect to the permeability of the mortar used for the joints and for the plaster. The test results showed that the equivalent permeability values, commonly used in the hygro-thermal design of structural brick walls, are decidedly lower compared to those in use.
La normativa vigente fornisce un metodo per il calcolo della prestazione igrometrica di una parete multistrato (UNI 10350) che adotta delle ipotesi semplificative che non tengono conto di aspetti importanti, quali la dinamica dell’adsorbimento capillare. Il valore di resistenza globale alla trasmissione del vapore, da utilizzare nella verifica, attualmente è stimato attraverso il valore di permeabilità fornito dalla UNI 10351, indipendentemente dalla geometria del blocco e dal tipo di laterizio. Nell’ambito del Progetto Finalizzato MSTA2 del CNR, è stata realizzata dal Politecnico di Bari una serie di misure della permeanza al vapore d’acqua di pareti di blocchi forati intonacate. La sperimentazione, condotta su quattro tipi di parete con laterizio normale e alleggerito in pasta, ha mostrato una scarsa sensibilità della resistenza alla diffusione del vapore d’acqua al variare della pressione di vapore o del suo gradiente. È emersa l’importanza della permeabilità al vapore d’acqua del laterizio rispetto alla permeabilità della malta utilizzata per i giunti e per l’intonaco. I risultati sperimentali hanno dimostrato che i valori di permeabilità equivalente, comunemente usati nella progettazione termoigrometrica delle pareti in laterizio, sono decisamente inferiori rispetto a quelli in opera.
Il trasporto del vapore d’acqua in pareti di blocchi forati = Water vapour transfer in hollow block walls / Bondi, Paolo; Stefanizzi, P.; Dondi, M.; Mazzanti, F.; Raimondo, M.. - In: L'INDUSTRIA DEI LATERIZI. - ISSN 1123-8208. - STAMPA. - 84:novembre-dicembre 2003(2003), pp. 1-8.
Il trasporto del vapore d’acqua in pareti di blocchi forati = Water vapour transfer in hollow block walls
Bondi, Paolo;P. Stefanizzi;
2003-01-01
Abstract
Current standards provide a method for calculating the hygrometric performance of a multilayered wall (UNI 10350) that adopts simplified hypotheses that do not take into account important aspects like the dynamics of capillary adsorption. The value of the global resistance to the transmission of vapour, to be used in the control, is currently assessed using the permeability value supplied by UNI 10351, regardless of the geometry of the block and the type of structural brick. Within the framework of the Progetto Finalizzato MSTA2 from CNR, Bari Polytechnic carried out a series of measurements of the permeability to steam of walls made of plastered hollow blocks. The test, conducted on four types of walls with normal structural bricks and light weight ones, demonstrated little sensitivity to the resistance to the diffusion of water vapour with a variation of the vapour pressure or its gradient. What emerged was the importance of the permeability to water vapour of the brick with respect to the permeability of the mortar used for the joints and for the plaster. The test results showed that the equivalent permeability values, commonly used in the hygro-thermal design of structural brick walls, are decidedly lower compared to those in use.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.