The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover, an increased detector stability has been obtained by automatically taking into account temperature and atmospheric pressure variations in the CMS cavern.

Uniformity and stability of the CMS RPC detector at the LHC / S., Costantini; K., Beernaert; A., Cimmino; G., Garcia; J., Lellouch; A., Marinov; A., Ocampo; N., Strobbe; F., Thyssen; M., Tytgat; P., Verwilligen; E., Yazgan; N., Zaganidis; A., Dimitrov; R., Hadjiiska; L., Litov; B., Pavlov; P., Petkov; A., Aleksandrov; V., Genchev; P., Iaydjiev; M., Rodozov; M., Shopova; G., Sultanov; Y., Ban; J., Cai; Y., Ge; Q., Li; S., Qian; Z., Xue; C., Avila; L. F., Chaparro; J. P., Gomez; B., Gomez Moreno; A. F., Osorio Oliveros; J. C., Sanabria; Y., Assran; A., Sharma; M., Abbrescia; C., Calabria; A., Colaleo; F., Loddo; M., Maggi; Pugliese, Gabriella Maria Incoronata; L., Benussi; S., Bianco; S., Colafranceschi; D., Piccolo; S., Buontempo; C., Carrillo; O., Iorio; P., Paolucci; U., Berzano; M., Gabusi; P., Vitulo; M., Kang; K. S., Lee; S. K., Park; S., Shin; Y., Choi; J., Goh; M. S., Kim; H., Seo; M., Shoaib. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:3(2013). [10.1088/1748-0221/8/03/P03017]

Uniformity and stability of the CMS RPC detector at the LHC

PUGLIESE, Gabriella Maria Incoronata;
2013-01-01

Abstract

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover, an increased detector stability has been obtained by automatically taking into account temperature and atmospheric pressure variations in the CMS cavern.
2013
Uniformity and stability of the CMS RPC detector at the LHC / S., Costantini; K., Beernaert; A., Cimmino; G., Garcia; J., Lellouch; A., Marinov; A., Ocampo; N., Strobbe; F., Thyssen; M., Tytgat; P., Verwilligen; E., Yazgan; N., Zaganidis; A., Dimitrov; R., Hadjiiska; L., Litov; B., Pavlov; P., Petkov; A., Aleksandrov; V., Genchev; P., Iaydjiev; M., Rodozov; M., Shopova; G., Sultanov; Y., Ban; J., Cai; Y., Ge; Q., Li; S., Qian; Z., Xue; C., Avila; L. F., Chaparro; J. P., Gomez; B., Gomez Moreno; A. F., Osorio Oliveros; J. C., Sanabria; Y., Assran; A., Sharma; M., Abbrescia; C., Calabria; A., Colaleo; F., Loddo; M., Maggi; Pugliese, Gabriella Maria Incoronata; L., Benussi; S., Bianco; S., Colafranceschi; D., Piccolo; S., Buontempo; C., Carrillo; O., Iorio; P., Paolucci; U., Berzano; M., Gabusi; P., Vitulo; M., Kang; K. S., Lee; S. K., Park; S., Shin; Y., Choi; J., Goh; M. S., Kim; H., Seo; M., Shoaib. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:3(2013). [10.1088/1748-0221/8/03/P03017]
Uniformity and stability of the CMS RPC detector at the LHC / S., Costantini; K., Beernaert; A., Cimmino; G., Garcia; J., Lellouch; A., Marinov; A., Ocampo; N., Strobbe; F., Thyssen; M., Tytgat; P., Verwilligen; E., Yazgan; N., Zaganidis; A., Dimitrov; R., Hadjiiska; L., Litov; B., Pavlov; P., Petkov; A., Aleksandrov; V., Genchev; P., Iaydjiev; M., Rodozov; M., Shopova; G., Sultanov; Y., Ban; J., Cai; Y., Ge; Q., Li; S., Qian; Z., Xue; C., Avila; L. F., Chaparro; J. P., Gomez; B., Gomez Moreno; A. F., Osorio Oliveros; J. C., Sanabria; Y., Assran; A., Sharma; M., Abbrescia; C., Calabria; A., Colaleo; F., Loddo; M., Maggi; Pugliese, Gabriella Maria Incoronata; L., Benussi; S., Bianco; S., Colafranceschi; D., Piccolo; S., Buontempo; C., Carrillo; O., Iorio; P., Paolucci; U., Berzano; M., Gabusi; P., Vitulo; M., Kang; K. S., Lee; S. K., Park; S., Shin; Y., Choi; J., Goh; M. S., Kim; H., Seo; M., Shoaib. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 8:3(2013). [10.1088/1748-0221/8/03/P03017]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/3311
Citazioni
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 8
social impact