The CMS muon system is conceived for trigger and muon track reconstruction. The redundancy and robustness of the system are guaranteed by three complementary subsystems: drift tube in the barrel, cathode strip chamber in the end-cap and resistive plate chamber in barrel and end-cap. The installation of muon stations and read-out trigger electronic has been completed in middle 2007. Since than, a remarkable effort has been addressed to the detector commissioning in order to ensure the readiness of the hardware/software chain for the LHC start up operation. At the end of 2007, a test of an entire CMS slice has been performed. involving about 5% of muon stations. Several thousand cosmic muons events have been collected. Performance of the barrel chambers are reported. (C) 2008 Elsevier B.V. All rights reserved.
Resistive plate chamber commissioning and performance in CMS / Roselli, G.; Abbrescia, M.; Iaselli, Giuseppe; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, Gabriella Maria Incoronata; Romano, F.; Trentadue, R.; Tupputi, S.; Rajan, R. T.; Shinde, Y.; Colaleo, A.; Loddo, F.; Maggi, M.; Ranieri, A.; Lomidze, D.; Paolucci, P.; Piccolo, D.; Cimmino, A.; Noli, P.; Cavallo, N.; Sciacca, C.; Baesso, P.; Necchi, M.; Pagano, D.; Ratti, S. P.; Vitulo, P.; Viviani, C.; Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F. L.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Genchev, V.; Iaydjiev, P.; Panev, B.; Stoykova, S.; Sultanov, G.; Trayanov, R.; Guida, R.; Carrillo Montoya, C. A.; Ocampo Rios, A. A.; Polese, G.; Tuuva, T.; Bunkowski, K.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Kudla, I. M.; Pietrusinski, M.; Bluj, M.; Fruboes, T.; Gorski, M.; Szleper, M.; Wrochna, G.; Pozniak, K. T.; Zabolotny, W.; Whitaker, William. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 602:3(2009), pp. 696-699. [10.1016/j.nima.2008.12.092]
Resistive plate chamber commissioning and performance in CMS
Roselli, G.;Abbrescia, M.;IASELLI, Giuseppe;Marangelli, B.;Natali, S.;Nuzzo, S.;PUGLIESE, Gabriella Maria Incoronata;Romano, F.;Trentadue, R.;Tupputi, S.;Rajan, R. T.;Shinde, Y.;Colaleo, A.;Loddo, F.;Maggi, M.;Ranieri, A.;Lomidze, D.;Paolucci, P.;Piccolo, D.;Cimmino, A.;Noli, P.;Cavallo, N.;Sciacca, C.;Baesso, P.;Necchi, M.;Pagano, D.;Ratti, S. P.;Vitulo, P.;Viviani, C.;Benussi, L.;Bertani, M.;Bianco, S.;Fabbri, F. L.;Dimitrov, A.;Litov, L.;Pavlov, B.;Petkov, P.;Genchev, V.;Iaydjiev, P.;Panev, B.;Stoykova, S.;Sultanov, G.;Trayanov, R.;Guida, R.;Carrillo Montoya, C. A.;Ocampo Rios, A. A.;Polese, G.;Tuuva, T.;Bunkowski, K.;Doroba, K.;Kalinowski, A.;Konecki, M.;Krolikowski, J.;Kudla, I. M.;Pietrusinski, M.;Bluj, M.;Fruboes, T.;Gorski, M.;Szleper, M.;Wrochna, G.;Pozniak, K. T.;Zabolotny, W.;Whitaker, William
2009-01-01
Abstract
The CMS muon system is conceived for trigger and muon track reconstruction. The redundancy and robustness of the system are guaranteed by three complementary subsystems: drift tube in the barrel, cathode strip chamber in the end-cap and resistive plate chamber in barrel and end-cap. The installation of muon stations and read-out trigger electronic has been completed in middle 2007. Since than, a remarkable effort has been addressed to the detector commissioning in order to ensure the readiness of the hardware/software chain for the LHC start up operation. At the end of 2007, a test of an entire CMS slice has been performed. involving about 5% of muon stations. Several thousand cosmic muons events have been collected. Performance of the barrel chambers are reported. (C) 2008 Elsevier B.V. All rights reserved.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/356
Citazioni
4
3
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.