Universal wind power generation systems (WPGS) should be able to operate both grid-connected and in island mode without compromising the power quality. The control system of a universal WPGS has to manage the different connections and provide harmonic disturbances compensation. This paper proposes the use of resonant filters for harmonics rejection both in grid-connected and island operation mode but within a different control structure. The proposed control has been tested in simulation.
Harmonic Control Strategy for Universal Operation of Wind Turbine Systems / Nagliero, A.; Mastromauro, R. A.; Ricchiuto, Domenico; Liserre, M.. - STAMPA. - (2011). (Intervento presentato al convegno 3rd IEEE International Conference on Power Engineering, Energy and Electrical Drives, PowerEng2011 tenutosi a Torremolinos, Malaga; Spain nel May 11-13, 2011) [10.1109/PowerEng.2011.6036427].
Harmonic Control Strategy for Universal Operation of Wind Turbine Systems
Ricchiuto, Domenico;M. Liserre
2011-01-01
Abstract
Universal wind power generation systems (WPGS) should be able to operate both grid-connected and in island mode without compromising the power quality. The control system of a universal WPGS has to manage the different connections and provide harmonic disturbances compensation. This paper proposes the use of resonant filters for harmonics rejection both in grid-connected and island operation mode but within a different control structure. The proposed control has been tested in simulation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.