In previous works, the authors have explored the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In this paper, the repeatability of the measurements obtained with the proposed method is evaluated, by employing an ad-hoc experimental procedure. Preliminary results demonstrate that the method shows a good repeatability; nevertheless, there are still some issues that should be solved.

Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion / Cataldo, A; Cannazza, G; De Benedetto, E; Giaquinto, Nicola; Trotta, Amerigo. - STAMPA. - (2012), pp. 203-207. (Intervento presentato al convegno IEEE Symposium on Medical Measurements and Applications, MeMeA 2012 tenutosi a Budapest, Hungary nel May 18-19, 2012) [10.1109/MeMeA.2012.6226673].

Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion

GIAQUINTO, Nicola;TROTTA, Amerigo
2012-01-01

Abstract

In previous works, the authors have explored the use of a microwave reflectometry-based system for the automatic control and real-time monitoring of the flow and of the liquid level in intravenous medical infusions. In this paper, the repeatability of the measurements obtained with the proposed method is evaluated, by employing an ad-hoc experimental procedure. Preliminary results demonstrate that the method shows a good repeatability; nevertheless, there are still some issues that should be solved.
2012
IEEE Symposium on Medical Measurements and Applications, MeMeA 2012
978-1-4673-0880-9
Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion / Cataldo, A; Cannazza, G; De Benedetto, E; Giaquinto, Nicola; Trotta, Amerigo. - STAMPA. - (2012), pp. 203-207. (Intervento presentato al convegno IEEE Symposium on Medical Measurements and Applications, MeMeA 2012 tenutosi a Budapest, Hungary nel May 18-19, 2012) [10.1109/MeMeA.2012.6226673].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/52764
Citazioni
  • Scopus 17
  • ???jsp.display-item.citation.isi??? ND
social impact