The TOTEM experiment will detect leading protons scattered in angles of microradians from the interaction point at the large hadron collider. This will be achieved using detectors with a minimized dead area at the edge. The collaboration has developed an innovative structure at the detector edge reducing the conventional dead width to less than 100 mu m, still using standard planar fabrication technology. In this new development, the current of the surface is decoupled from the sensitive volume current within a few tens of micrometers. The basic working principle is explained in this paper. Final size detectors have been produced using this approach. The current-voltage and current-temperature characteristics of the detectors were studied and the detectors were successfully tested in a coasting beam experiment.

Final size planar edgeless silicon detectors for the TOTEM experiment / Noschis, E; Alagoz, E; Anelli, G; Avati, V; Berardi, Vincenzo; Boccone, V; Bozzo, M; Brucken, E; Buzzo, A; Catanesi, M. G.; Cereseto, R; Cuneo, S; DA VIA, C; Deile, M; Dinapoli, R; Eggert, K; Egorov, N; Eremin, I; Ferro, F; Hasi, J; Haug, F; Heino, J; Jarron, P; Kalliopuska, J; Kaspar, J; Kok, A; Kozlov, Y; Kundrat, W; Kurvinen, K; Lauhakangas, R; Lokajicek, M; Luntama, T; Macina, D; Macri, M; Minutoli, S; Mirabito, L; Morelli, A; Musico, P; Negri, M; Niewiadomski, H; Oljemark, F; Orava, R; Oriunno, M; Osterberg, K; Perrot, A. L.; Puppo, R; Radermacher, E; Radicioni, E; Saarikko, H; Santroni, A; Sette, G; Sidorov, A; Siegrist, P; Smotlacha, J; Snoeys, W; Taylor, C; Watts, S; Whitmore, J.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 563:1(2006), pp. 41-44. [10.1016/j.nima.2006.01.111]

Final size planar edgeless silicon detectors for the TOTEM experiment

BERARDI, Vincenzo;
2006-01-01

Abstract

The TOTEM experiment will detect leading protons scattered in angles of microradians from the interaction point at the large hadron collider. This will be achieved using detectors with a minimized dead area at the edge. The collaboration has developed an innovative structure at the detector edge reducing the conventional dead width to less than 100 mu m, still using standard planar fabrication technology. In this new development, the current of the surface is decoupled from the sensitive volume current within a few tens of micrometers. The basic working principle is explained in this paper. Final size detectors have been produced using this approach. The current-voltage and current-temperature characteristics of the detectors were studied and the detectors were successfully tested in a coasting beam experiment.
2006
Final size planar edgeless silicon detectors for the TOTEM experiment / Noschis, E; Alagoz, E; Anelli, G; Avati, V; Berardi, Vincenzo; Boccone, V; Bozzo, M; Brucken, E; Buzzo, A; Catanesi, M. G.; Cereseto, R; Cuneo, S; DA VIA, C; Deile, M; Dinapoli, R; Eggert, K; Egorov, N; Eremin, I; Ferro, F; Hasi, J; Haug, F; Heino, J; Jarron, P; Kalliopuska, J; Kaspar, J; Kok, A; Kozlov, Y; Kundrat, W; Kurvinen, K; Lauhakangas, R; Lokajicek, M; Luntama, T; Macina, D; Macri, M; Minutoli, S; Mirabito, L; Morelli, A; Musico, P; Negri, M; Niewiadomski, H; Oljemark, F; Orava, R; Oriunno, M; Osterberg, K; Perrot, A. L.; Puppo, R; Radermacher, E; Radicioni, E; Saarikko, H; Santroni, A; Sette, G; Sidorov, A; Siegrist, P; Smotlacha, J; Snoeys, W; Taylor, C; Watts, S; Whitmore, J.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 563:1(2006), pp. 41-44. [10.1016/j.nima.2006.01.111]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/551
Citazioni
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 17
social impact