The development of the NOE calorimeter, based on scintillating fiber technology, has undergone four years of intense R&D activity. Measurements of light attenuation and time resolution have been carried out on a variety of commercially available scintillating fibers. Both these parameters are important for the optimization of the design of the NOE calorimeter. Experimental results on the fiber attenuation length and light yield make us confident on the possibility to build a cross-section calorimeter without noticeable loss of signal. The time resolution is resulted to be of the order of 1 ns, sufficient for up/down discrimination in the final calorimeter setup, by means of the time-of-flight method. Several tests performed to optimize the elementary cell of the calorimeter are also described.
R&D results from the NOE scintillating fiber calorimeter / Alexandrov, K. V.; Barbarino, G. C.; Bernardini, P.; Brigida, M.; Campana, D.; Candela, A.; Caruso, R.; Cassese, F.; Ceres, A.; D'Aquino, B.; De Cataldo, G.; De Mitri, I.; Di Credico, A.; Favuzzi, C.; Fusco, P.; Gargano, F.; Giglietto, N.; Giordano, F.; Grillo, A.; Guarino, F.; Lauro, A.; Leone, A.; Loparco, F.; Mancarella, G.; Martello, D.; Mazziotta, M. N.; Mongelli, M.; Osteria, G.; Palladino, V.; Passeggio, G.; Perchiazzi, M.; Perrino, R.; Pinto, C.; Pontoriere, G.; Rainò, A.; Rocco, R.; Romanucci, E.; Sacchetti, A.; Scapparone, E.; Spinelli, P.; Surdo, A.; Tikhomirov, V.; Vaccina, A.; Vanzanella, E.; Zilli, A.; Weber, M.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 459:1-2(2001), pp. 123-134. [10.1016/S0168-9002(00)01001-9]
R&D results from the NOE scintillating fiber calorimeter
The development of the NOE calorimeter, based on scintillating fiber technology, has undergone four years of intense R&D activity. Measurements of light attenuation and time resolution have been carried out on a variety of commercially available scintillating fibers. Both these parameters are important for the optimization of the design of the NOE calorimeter. Experimental results on the fiber attenuation length and light yield make us confident on the possibility to build a cross-section calorimeter without noticeable loss of signal. The time resolution is resulted to be of the order of 1 ns, sufficient for up/down discrimination in the final calorimeter setup, by means of the time-of-flight method. Several tests performed to optimize the elementary cell of the calorimeter are also described.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/5955
Citazioni
7
6
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.