This paper presents a two-dimensional numerical study on the nonlinear seismic response of buildings equipped with two types of energy dissipators: Constant Friction Slip Braces (CFSB) and Adding Damping and Stiffness (ADAS). Three types of reinforced concrete buildings with 3, 7 and 15 storeys, representatives of the short-medium- and long-period ranges, are considered. Dissipators are placed in steel diagonal braces in all the floors. The sliding threshold (or yielding) forces for each mechanism are selected using two different criteria: (i) they are taken as 50, 75 and 100 per cent of those generated by the equivalent static lateral forces recommended by the UBC-91 for a ductile moment resisting frame and (ii) they are constant in the whole building (this constant value is chosen equal to the maximum forces obtained with the previous criterion). The input consists of ten recorded earthquakes (normalized with respect to their Housner intensity) corresponding to medium and stiff local soil conditions. Average values on the ten registers are given for the maximum horizontal displacement, the base shear, the energy dissipated and the interstorey drift. The possibility of failure in some devices has been numerically simulated to assess the robustness of the system. The obtained results show that both devices are useful to reduce the response compared to the bare frame and that CFSB is more efficient than ADAS; for 7- and 15-storey frames the lateral displacement with CFSB is even smaller than the one for the braced frame (rigid connections instead of dissipators). The conclusions are expected to provide simple design guidelines.

Numerical Efficiency Assessment of Energy Dissipators for Seismic Protection of Buildings / Foti, Dora; Bozzo, L.; L� Almansa, F.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 27:6(1998), pp. 543-556. [10.1002/(SICI)1096-9845(199806)27:6<543::AID-EQE733>3.0.CO;2-9]

Numerical Efficiency Assessment of Energy Dissipators for Seismic Protection of Buildings

FOTI, Dora;
1998-01-01

Abstract

This paper presents a two-dimensional numerical study on the nonlinear seismic response of buildings equipped with two types of energy dissipators: Constant Friction Slip Braces (CFSB) and Adding Damping and Stiffness (ADAS). Three types of reinforced concrete buildings with 3, 7 and 15 storeys, representatives of the short-medium- and long-period ranges, are considered. Dissipators are placed in steel diagonal braces in all the floors. The sliding threshold (or yielding) forces for each mechanism are selected using two different criteria: (i) they are taken as 50, 75 and 100 per cent of those generated by the equivalent static lateral forces recommended by the UBC-91 for a ductile moment resisting frame and (ii) they are constant in the whole building (this constant value is chosen equal to the maximum forces obtained with the previous criterion). The input consists of ten recorded earthquakes (normalized with respect to their Housner intensity) corresponding to medium and stiff local soil conditions. Average values on the ten registers are given for the maximum horizontal displacement, the base shear, the energy dissipated and the interstorey drift. The possibility of failure in some devices has been numerically simulated to assess the robustness of the system. The obtained results show that both devices are useful to reduce the response compared to the bare frame and that CFSB is more efficient than ADAS; for 7- and 15-storey frames the lateral displacement with CFSB is even smaller than the one for the braced frame (rigid connections instead of dissipators). The conclusions are expected to provide simple design guidelines.
1998
Numerical Efficiency Assessment of Energy Dissipators for Seismic Protection of Buildings / Foti, Dora; Bozzo, L.; L� Almansa, F.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 27:6(1998), pp. 543-556. [10.1002/(SICI)1096-9845(199806)27:6<543::AID-EQE733>3.0.CO;2-9]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/6076
Citazioni
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 28
social impact