The Resistive Plate Chambers [M. Abbrescia, et al., Nucl. Instr. and Meth. A 550 (2005) 1161 are used in the CMS experiment [CMS Collaboration, The CMS experiment at the CERN LHC 2008, J. Inst. 3 (2008) S08004] as a dedicated muon trigger both in barrel and endcap system. About 4000 m(2) of double gap RPCs have been produced and have been installed in the experiment since more than one and half Years. The full barrel system and a fraction of the endcaps have been monitored to study dark current behaviour and system stability, and have been extensively commissioned with Cosmic Rays collected by the full CMS experiment. (C) 2009 Elsevier B.V. All rights reserved.

Resistive Plate Chambers performance with Cosmic Rays in the CMS experiment / Piccolo, D.; Darmenov, N.; Genchev, V.; Iaydjiev, P.; Stoykova, S.; Sultanov, G.; Trayanov, R.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Marinov, A.; Thyssen, F.; Tytgat, M.; Verwilligen, P.; Zaganidis, N.; Akimenko, S.; Ball, A.; Crotty, I.; Guida, R.; Sharma, A.; Van Doninck, W.; Abbrescia, M.; Iaselli, G.; Marangelli, B.; Nuzzo, S.; Pugliese, G.; Romano, F.; Roselli, G.; Trentadue, R.; Tupputi, S.; Colaleo, A.; Loddo, F.; Ranieri, A.; Cimmino, A.; Sciacca, C.; Buontempo, S.; Cavallo, N.; Fabozzi, F.; Lomidtze, D.; Paolucci, P.; Benussi, L.; Bertani, M.; Bianco, S.; Colafranceschi, S.; Fabbri, F. L.; Baesso, P.; Pagano, D.; Ratti, S. P.; Vitulo, P.; Viviani, C.; Avila, C.; Carrillo, C.; Gomez, B.; Ocampo, A.; Osorio, A.; Sanabria, J. C.; Polese, G.; Tuuva, T.; Bunkowski, K.; Cwiok, M.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Kierzkowski, K.; Kudla, I. M.; Oklins, W.; Pietrusinski, M.; Bluj, M.; Fruboes, T.; Gorski, M.; Kazana, M.; Szleper, M.; Wrochna, G.; Zalewski, P.; Poznik, K. T.; Zabolotny, W.; Ban, Y.; Qian, S. J.; Ye, Y. L.; Ahmad, M.; Ahmed, I.; Ahmed, W.; Asghar, M. I.; Butt, J. B.; Hoorani, H. R.; Hussain, I.; Khan, W. A.; Khurshid, T.; Malik, I. A.; Muhammad, S.; Qazi, S. F.; Shahzad, H.; Cho, S. W.; Jo, M.; Hong, B.; Kim, C.; Kim, H. C.; Kim, J. H.; Lee, H. S.; Lee, K. S.; Moon, D. H.; Park, S.; Rhee, H. B.; Seo, E. S.; Shin, S. S.; Sim, K. S.; Lee, J. S.; Lee, S. E.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 617:1-3(2010), pp. 180-182. [10.1016/j.nima.2009.06.092]

Resistive Plate Chambers performance with Cosmic Rays in the CMS experiment

Iaselli, G.;Pugliese, G.;
2010-01-01

Abstract

The Resistive Plate Chambers [M. Abbrescia, et al., Nucl. Instr. and Meth. A 550 (2005) 1161 are used in the CMS experiment [CMS Collaboration, The CMS experiment at the CERN LHC 2008, J. Inst. 3 (2008) S08004] as a dedicated muon trigger both in barrel and endcap system. About 4000 m(2) of double gap RPCs have been produced and have been installed in the experiment since more than one and half Years. The full barrel system and a fraction of the endcaps have been monitored to study dark current behaviour and system stability, and have been extensively commissioned with Cosmic Rays collected by the full CMS experiment. (C) 2009 Elsevier B.V. All rights reserved.
2010
Resistive Plate Chambers performance with Cosmic Rays in the CMS experiment / Piccolo, D.; Darmenov, N.; Genchev, V.; Iaydjiev, P.; Stoykova, S.; Sultanov, G.; Trayanov, R.; Dimitrov, A.; Litov, L.; Pavlov, B.; Petkov, P.; Marinov, A.; Thyssen, F.; Tytgat, M.; Verwilligen, P.; Zaganidis, N.; Akimenko, S.; Ball, A.; Crotty, I.; Guida, R.; Sharma, A.; Van Doninck, W.; Abbrescia, M.; Iaselli, G.; Marangelli, B.; Nuzzo, S.; Pugliese, G.; Romano, F.; Roselli, G.; Trentadue, R.; Tupputi, S.; Colaleo, A.; Loddo, F.; Ranieri, A.; Cimmino, A.; Sciacca, C.; Buontempo, S.; Cavallo, N.; Fabozzi, F.; Lomidtze, D.; Paolucci, P.; Benussi, L.; Bertani, M.; Bianco, S.; Colafranceschi, S.; Fabbri, F. L.; Baesso, P.; Pagano, D.; Ratti, S. P.; Vitulo, P.; Viviani, C.; Avila, C.; Carrillo, C.; Gomez, B.; Ocampo, A.; Osorio, A.; Sanabria, J. C.; Polese, G.; Tuuva, T.; Bunkowski, K.; Cwiok, M.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Kierzkowski, K.; Kudla, I. M.; Oklins, W.; Pietrusinski, M.; Bluj, M.; Fruboes, T.; Gorski, M.; Kazana, M.; Szleper, M.; Wrochna, G.; Zalewski, P.; Poznik, K. T.; Zabolotny, W.; Ban, Y.; Qian, S. J.; Ye, Y. L.; Ahmad, M.; Ahmed, I.; Ahmed, W.; Asghar, M. I.; Butt, J. B.; Hoorani, H. R.; Hussain, I.; Khan, W. A.; Khurshid, T.; Malik, I. A.; Muhammad, S.; Qazi, S. F.; Shahzad, H.; Cho, S. W.; Jo, M.; Hong, B.; Kim, C.; Kim, H. C.; Kim, J. H.; Lee, H. S.; Lee, K. S.; Moon, D. H.; Park, S.; Rhee, H. B.; Seo, E. S.; Shin, S. S.; Sim, K. S.; Lee, J. S.; Lee, S. E.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 617:1-3(2010), pp. 180-182. [10.1016/j.nima.2009.06.092]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/6265
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact