The energy response and the resolution of a hadron calorimeter test module prepared by the ALEPH collaboration at LEP have been studied between 5 and 50 GeV. The energy resolution for pions follows a law for orthogonally incident particles. Effects of different incident polar angles (θ = 90°, 60°, 50°) are studied. The wire readout and the trigger capability are also discussed.

Performance of a limited streamer tube hadron calorimeter / Catanesi, M. G.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Natali, S.; Nuzzo, S.; Ranieri, A.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Tupputi, R.; Zito, G.; Baldini, R.; Battistoni, G.; Bencivenni, G.; Bologna, G.; Campana, P.; Capon, G.; Celani, F.; Chiarella, V.; Ciocio, A.; D'Ettore-Piazzoli, B.; Felici, G.; Laurelli, P.; Mannocchi, G. P.; Murtas, G. P.; Nicoletti, G.; Pallotta, M.; Picchi, P.; Batignani, G.; Bradaschia, C.; Bottigli, U.; Foa', L.; Giassi, A.; Giorgi, M. A.; Lin, J. F.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 247:3(1986), pp. 438-444. [10.1016/0168-9002(86)90405-5]

Performance of a limited streamer tube hadron calorimeter

Iaselli, G.;Maggi, G.;
1986-01-01

Abstract

The energy response and the resolution of a hadron calorimeter test module prepared by the ALEPH collaboration at LEP have been studied between 5 and 50 GeV. The energy resolution for pions follows a law for orthogonally incident particles. Effects of different incident polar angles (θ = 90°, 60°, 50°) are studied. The wire readout and the trigger capability are also discussed.
1986
Performance of a limited streamer tube hadron calorimeter / Catanesi, M. G.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Natali, S.; Nuzzo, S.; Ranieri, A.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Tupputi, R.; Zito, G.; Baldini, R.; Battistoni, G.; Bencivenni, G.; Bologna, G.; Campana, P.; Capon, G.; Celani, F.; Chiarella, V.; Ciocio, A.; D'Ettore-Piazzoli, B.; Felici, G.; Laurelli, P.; Mannocchi, G. P.; Murtas, G. P.; Nicoletti, G.; Pallotta, M.; Picchi, P.; Batignani, G.; Bradaschia, C.; Bottigli, U.; Foa', L.; Giassi, A.; Giorgi, M. A.; Lin, J. F.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 247:3(1986), pp. 438-444. [10.1016/0168-9002(86)90405-5]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11589/7909
Citazioni
  • Scopus 30
  • ???jsp.display-item.citation.isi??? ND
social impact